EN
TR
Seismic Assessment of Electrical Equipment in Power Substations: A Case Study for Circuit Breakers
Öz
Electric power is essential in post-earthquake periods for the continuous functionality of disaster management and emergency services. In addition, interruption of electric power can cause significant economic losses due to downtime of critical facilities. Therefore, it is very important to maintain seismic safety of electric power systems and components. There are existing seismic regulations and standards regarding electric power systems, especially in the United States of America (USA) and Europe. A similar regulation has been prepared recently in Türkiye, which is a country in a seismically active region. This study focuses on the current state of practice regarding the seismic assessment of electrical equipment in power stations and implementation of the regulations on seismic qualification of these systems. Among many electrical equipment, circuit breakers have been selected for case study. The seismic assessment of the selected high voltage equipment has been performed according to the new regulation under the seismic hazard specifically defined for Türkiye. The case study experiment presents the new methodology in evaluating and classifying the seismic response of high voltage electrical equipment and provides insight to the expected behaviour of circuit breakers under earthquake induced action.
Anahtar Kelimeler
Kaynakça
- Schiff, A., Guide to improved earthquake performance of electrical power systems, Rep. No. NIST GCR 98-757, National Institute for Standards and Testing, Washington, DC, USA, 1998.
- MCEER. The Chi-Chi, Taiwan earthquake of September 21, 1999: Reconnaissance Report. Rep. No. MCEER 00-0003. Eds: Lee, G.C. and Loh, C.H. Multidisciplinary Center for Earthquake Engineering Research, Buffalo, New York, USA, 2000.
- Fujisaki, E., Takhirov, S., Xie, Q., Mosalam, K.M. Seismic vulnerability of power supply: Lessons learned from recent earthquakes and future horizons research. Proceedings of the 9th International Conference on Structural Dynamics (EURODYN 2014), 30 June- 2 July, Porto, Portugal, 2014.
- Technical Council on Lifeline Earthquake Engineering (TCLEE). Chile Earthquake of 2010: Lifeline Performance, TCLEE Monograph No. 36. Eds: Tang, A.K. and Eidinger, J.M. American Society of Civil Engineers, Reston, Virginia, 2013.
- Technical Council on Lifeline Earthquake Engineering (TCLEE). Christchurch, New Zealand Earthquake Sequence of Mw 7.1 September 04, 2010, Mw 6.3 February 22, 2011, Mw 6.0 June 13, 2011: Lifeline Performance. TCLEE Monograph No. 40. Eds: Eidinger, J.M. and Tang, A.K. American Society of Civil Engineers, Reston, Virginia, 2012.
- O’Rourke, T.D., Erdogan, F.H., Savage, W.U., Lund, L.V., Tang, A., Water, gas, electric power and telecommunications performance – 1999 Kocaeli earthquake. Earthquake Spectra 16(S1), 377-402, 2000.
- MCEER. The Marmara Turkey Earthquake of August 17, 1999: Reconnaissance Report. Rep. No. MCEER 00-0001, Ed: Scawthorn C. Multidisciplinary Center for Earthquake Engineering Research, Buffalo, New York, USA, 2000.
- Uckan, E. Lifeline Damage Caused in the 23 October (Mw=7.2) 2011 and 9 November (M=5.6) 2011, Van Earthquakes in Eastern Turkey. Sixth China-Japan-US Trilateral Symposium on Lifeline Earthquake Engineering, 28 May -1 June, Chengdu, China, 2013.
Ayrıntılar
Birincil Dil
İngilizce
Konular
İnşaat Mühendisliği
Bölüm
Araştırma Makalesi
Erken Görünüm Tarihi
12 Mart 2024
Yayımlanma Tarihi
1 Temmuz 2024
Gönderilme Tarihi
28 Ocak 2023
Kabul Tarihi
1 Mart 2024
Yayımlandığı Sayı
Yıl 2024 Cilt: 35 Sayı: 4
APA
Kaatsız, K., Alıcı, F. S., & Erberik, M. A. (2024). Seismic Assessment of Electrical Equipment in Power Substations: A Case Study for Circuit Breakers. Turkish Journal of Civil Engineering, 35(4), 49-68. https://doi.org/10.18400/tjce.1241107
AMA
1.Kaatsız K, Alıcı FS, Erberik MA. Seismic Assessment of Electrical Equipment in Power Substations: A Case Study for Circuit Breakers. tjce. 2024;35(4):49-68. doi:10.18400/tjce.1241107
Chicago
Kaatsız, Kaan, Fırat Soner Alıcı, ve Murat Altuğ Erberik. 2024. “Seismic Assessment of Electrical Equipment in Power Substations: A Case Study for Circuit Breakers”. Turkish Journal of Civil Engineering 35 (4): 49-68. https://doi.org/10.18400/tjce.1241107.
EndNote
Kaatsız K, Alıcı FS, Erberik MA (01 Temmuz 2024) Seismic Assessment of Electrical Equipment in Power Substations: A Case Study for Circuit Breakers. Turkish Journal of Civil Engineering 35 4 49–68.
IEEE
[1]K. Kaatsız, F. S. Alıcı, ve M. A. Erberik, “Seismic Assessment of Electrical Equipment in Power Substations: A Case Study for Circuit Breakers”, tjce, c. 35, sy 4, ss. 49–68, Tem. 2024, doi: 10.18400/tjce.1241107.
ISNAD
Kaatsız, Kaan - Alıcı, Fırat Soner - Erberik, Murat Altuğ. “Seismic Assessment of Electrical Equipment in Power Substations: A Case Study for Circuit Breakers”. Turkish Journal of Civil Engineering 35/4 (01 Temmuz 2024): 49-68. https://doi.org/10.18400/tjce.1241107.
JAMA
1.Kaatsız K, Alıcı FS, Erberik MA. Seismic Assessment of Electrical Equipment in Power Substations: A Case Study for Circuit Breakers. tjce. 2024;35:49–68.
MLA
Kaatsız, Kaan, vd. “Seismic Assessment of Electrical Equipment in Power Substations: A Case Study for Circuit Breakers”. Turkish Journal of Civil Engineering, c. 35, sy 4, Temmuz 2024, ss. 49-68, doi:10.18400/tjce.1241107.
Vancouver
1.Kaan Kaatsız, Fırat Soner Alıcı, Murat Altuğ Erberik. Seismic Assessment of Electrical Equipment in Power Substations: A Case Study for Circuit Breakers. tjce. 01 Temmuz 2024;35(4):49-68. doi:10.18400/tjce.1241107
Cited By
Optimal seismic intensity measure selection for high voltage electrical substation equipment in various setup configurations
Soil Dynamics and Earthquake Engineering
https://doi.org/10.1016/j.soildyn.2024.109106Seismic Risk, Structural Vulnerabilities, and Retrofitting Solutions: Lessons from the 2023 Kahramanmaraş Earthquake
Osmaniye Korkut Ata Üniversitesi Fen Bilimleri Enstitüsü Dergisi
https://doi.org/10.47495/okufbed.1573919Dynamic behavior and structural vulnerability analysis of molded transformers in power plants during earthquakes
Journal of Asian Architecture and Building Engineering
https://doi.org/10.1080/13467581.2025.2602303