Araştırma Makalesi

Building's Controlled Seismic Isolation by Using Upper Horizontal Dampers and Stiff Core

Cilt: 34 Sayı: 3 1 Mayıs 2023
PDF İndir
EN

Building's Controlled Seismic Isolation by Using Upper Horizontal Dampers and Stiff Core

Öz

The fundamental period of the seismically isolated buildings may be close to that of the long period pulses of near-filed earthquakes, leading to very large lateral displacements in isolators, which in turn can considerably reduce the stability of isolators, increase the chance of collision of the isolated buildings to adjacent buildings, or even result in overturning of the isolated buildings. Therefore, it is important to control these types of buildings and reduce the amount of lateral displacement in their isolating system. In this study, by conducting a series of time history analyses for a set of five multi-story steel buildings with various numbers of stories from 3 to 14, each having a very stiff core structure and a set of crosswise viscous dampers, connecting the building structure to the core structure at the lowest and the top floors, as well as the same structures without the core structure and dampers, the effect of stiff core and dampers in reducing the lateral displacement at isolators has been shown. Results indicate that by the proposed technique, the lateral displacement of the base isolation system is significantly decreased particularly for low-rise buildings.

Anahtar Kelimeler

Kaynakça

  1. Erkus B, Johnson EA. Smart base‐isolated benchmark building part III: a sample controller for bilinear isolation. Structural Control and Health Monitoring: The Official Journal of the International Association for Structural Control and Monitoring and of the European Association for the Control of Structures. 2006 Mar; 13(2‐3):605-25; https://doi.org/10.1002/stc.101.
  2. Nagarajaiah S, Narasimhan S. Smart base isolated benchmark building part II: sample controllers for linear and friction isolation. InProc. 16th ASCE Engineering Mechanics Conference, July 2003 (pp. 16-18).
  3. He WL, Agrawal AK. Applications of several semi-active control systems to the benchmark base-isolated building. InProceedings of the ASCE Engineering Mechanics Conference 2004 Jun.
  4. Huang, S., Huang, M., & Lyu, Y. (2021). Seismic performance analysis of a wind turbine with a monopile foundation affected by sea ice based on a simple numerical method. Engineering applications of computational fluid mechanics, 15(1), 1113-1133.
  5. Feng, Y., Zhang, B., Liu, Y., Niu, Z., Dai, B., Fan, Y.,... Chen, X. (2021). A 200-225-GHz Manifold-Coupled Multiplexer Utilizing Metal Wave guides. IEEE Transactions on Microwave Theory and Techniques, 1.
  6. Kim SB, Spencer Jr BF, Yun CB. Sliding mode fuzzy control for smart base isolated building. In17th ASCE Engineering Mechanics Conference (EM2004), Newark, USA 2004 Jun 13.
  7. Bai, Y., Nardi, D. C., Zhou, X., Picón, R. A., & Flórez-López, J. (2021). A new comprehensive model of damage for flexural subassemblies prone to fatigue. Computers & Structures, 256, 106639.
  8. Reigles D, Symans MD. Application of supervisory fuzzy logic controller to the base-isolated benchmark structure. InProceedings of the ASCE Engineering Mechanics Conference 2004 Jun.

Ayrıntılar

Birincil Dil

İngilizce

Konular

İnşaat Mühendisliği

Bölüm

Araştırma Makalesi

Yazarlar

Mahmood Hosseını * Bu kişi benim
0000-0003-3142-4087
Kuzey Kıbrıs Türk Cumhuriyeti

Mohammad Sadegh Rohanımanesh Bu kişi benim
0000-0002-8426-8906
Iran

Erken Görünüm Tarihi

3 Mayıs 2023

Yayımlanma Tarihi

1 Mayıs 2023

Gönderilme Tarihi

20 Şubat 2022

Kabul Tarihi

3 Mart 2023

Yayımlandığı Sayı

Yıl 2023 Cilt: 34 Sayı: 3

Kaynak Göster

APA
Talebi Jouneghani, K., Hosseını, M., Rohanımanesh, M. S., & Raıssı, M. (2023). Building’s Controlled Seismic Isolation by Using Upper Horizontal Dampers and Stiff Core. Turkish Journal of Civil Engineering, 34(3), 1-42. https://doi.org/10.18400/tjce.1265467
AMA
1.Talebi Jouneghani K, Hosseını M, Rohanımanesh MS, Raıssı M. Building’s Controlled Seismic Isolation by Using Upper Horizontal Dampers and Stiff Core. tjce. 2023;34(3):1-42. doi:10.18400/tjce.1265467
Chicago
Talebi Jouneghani, Kourosh, Mahmood Hosseını, Mohammad Sadegh Rohanımanesh, ve Morteza Raıssı. 2023. “Building’s Controlled Seismic Isolation by Using Upper Horizontal Dampers and Stiff Core”. Turkish Journal of Civil Engineering 34 (3): 1-42. https://doi.org/10.18400/tjce.1265467.
EndNote
Talebi Jouneghani K, Hosseını M, Rohanımanesh MS, Raıssı M (01 Mayıs 2023) Building’s Controlled Seismic Isolation by Using Upper Horizontal Dampers and Stiff Core. Turkish Journal of Civil Engineering 34 3 1–42.
IEEE
[1]K. Talebi Jouneghani, M. Hosseını, M. S. Rohanımanesh, ve M. Raıssı, “Building’s Controlled Seismic Isolation by Using Upper Horizontal Dampers and Stiff Core”, tjce, c. 34, sy 3, ss. 1–42, May. 2023, doi: 10.18400/tjce.1265467.
ISNAD
Talebi Jouneghani, Kourosh - Hosseını, Mahmood - Rohanımanesh, Mohammad Sadegh - Raıssı, Morteza. “Building’s Controlled Seismic Isolation by Using Upper Horizontal Dampers and Stiff Core”. Turkish Journal of Civil Engineering 34/3 (01 Mayıs 2023): 1-42. https://doi.org/10.18400/tjce.1265467.
JAMA
1.Talebi Jouneghani K, Hosseını M, Rohanımanesh MS, Raıssı M. Building’s Controlled Seismic Isolation by Using Upper Horizontal Dampers and Stiff Core. tjce. 2023;34:1–42.
MLA
Talebi Jouneghani, Kourosh, vd. “Building’s Controlled Seismic Isolation by Using Upper Horizontal Dampers and Stiff Core”. Turkish Journal of Civil Engineering, c. 34, sy 3, Mayıs 2023, ss. 1-42, doi:10.18400/tjce.1265467.
Vancouver
1.Kourosh Talebi Jouneghani, Mahmood Hosseını, Mohammad Sadegh Rohanımanesh, Morteza Raıssı. Building’s Controlled Seismic Isolation by Using Upper Horizontal Dampers and Stiff Core. tjce. 01 Mayıs 2023;34(3):1-42. doi:10.18400/tjce.1265467

Cited By