Teknik Not

A novel bileaflet sparing technique during mitral valve replacement: Lafci’s fold down technique

Cilt: 12 Sayı: 2 30 Haziran 2021
  • Gökhan Lafçı
TR EN

A novel bileaflet sparing technique during mitral valve replacement: Lafci’s fold down technique

Öz

Sub-valvular apparatus preservation procedure is an additional technique to mitral valve replacement which decrease the prevalence of low cardiac output syndrome and associated complications that may be seen after mitral valve replacement. A number of surgical techniques for both bileaflet and posterior leaflet preservation have been described previously. We aimed to share how we do the bileaflet preservation with a modified technique, Lafci’s anterior leaflet fold down technique, in selected patients who underwent mitral valve replacement procedure.With absence of resection and use of same sutures for both sparing leaflet and fixing mechanical valve may shorten cross-clamping time, and so, we believe that this technique is simple, reproducible when it is appropriate for the patient’s existing anatomy.

Anahtar Kelimeler

Kaynakça

  1. 1. Starr A, Edwards ML. Mitral valve replacement: clinical experience with a ball prosthesis. Ann Surg 1961; 154 :726-40.
  2. 2. Lillehei CW. Value of preserving chordal integrity. Both experimental and clinical data (Discussion). J Thorac Cardiovasc Surg 1963; 46: 494-5.
  3. 3. Lillehei CW, Levy MJ, Bonnabeau RC. Complete mitral valve replacement preserving papillary muscle, chordae tendineae, annulus continuity. Circulation 1963; 28: 757.
  4. 4. Lillehei CW, Levy MJ, Bonnabeau RC. Mitral valve replacement with preservation of papillary muscles and chordae tendineae. J Thorac Cardiovasc Surg 1964; 47: 532-43.
  5. 5. Athanasiou T, Chow A, Rao C et al. Preservation of the mitral valve apparatus: evidence synthesis and critical reappraisal of surgical techniques. Eur J Cardiothorac Surg 2008; 33 :391-401.
  6. 6. Sintek CF, Pfeffer TA, Kochamba GS, Khonsari S. Mitral valve replacement: technique to preserve the subvalvular apparatus. Ann Thorac Surg 1995; 59: 1027-9.
  7. 7. Yun KL, Sintek CF, Miller DC et al. Randomized trial of partial versus complete chordal preservation methods of mitral valve replacement: a preliminary report. Circulation 1999; 100 :90-4.
  8. 8. Natsuaki M, Itoh T, Tomita S, Furukawa K, Yoshikai M, Suda H, Ohteki H. Importance of preserving the mitral subvalvular apparatus in mitral valve replacement. Ann Thorac Surg 1996; 61: 585-90.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Sağlık Kurumları Yönetimi

Bölüm

Teknik Not

Yazarlar

Gökhan Lafçı Bu kişi benim
Türkiye

Yayımlanma Tarihi

30 Haziran 2021

Gönderilme Tarihi

12 Aralık 2020

Kabul Tarihi

11 Mart 2021

Yayımlandığı Sayı

Yıl 2021 Cilt: 12 Sayı: 2

Kaynak Göster

APA
Lafçı, G. (2021). A novel bileaflet sparing technique during mitral valve replacement: Lafci’s fold down technique. Turkish Journal of Clinics and Laboratory, 12(2), 123-126. https://doi.org/10.18663/tjcl.908102
AMA
1.Lafçı G. A novel bileaflet sparing technique during mitral valve replacement: Lafci’s fold down technique. TJCL. 2021;12(2):123-126. doi:10.18663/tjcl.908102
Chicago
Lafçı, Gökhan. 2021. “A novel bileaflet sparing technique during mitral valve replacement: Lafci’s fold down technique”. Turkish Journal of Clinics and Laboratory 12 (2): 123-26. https://doi.org/10.18663/tjcl.908102.
EndNote
Lafçı G (01 Haziran 2021) A novel bileaflet sparing technique during mitral valve replacement: Lafci’s fold down technique. Turkish Journal of Clinics and Laboratory 12 2 123–126.
IEEE
[1]G. Lafçı, “A novel bileaflet sparing technique during mitral valve replacement: Lafci’s fold down technique”, TJCL, c. 12, sy 2, ss. 123–126, Haz. 2021, doi: 10.18663/tjcl.908102.
ISNAD
Lafçı, Gökhan. “A novel bileaflet sparing technique during mitral valve replacement: Lafci’s fold down technique”. Turkish Journal of Clinics and Laboratory 12/2 (01 Haziran 2021): 123-126. https://doi.org/10.18663/tjcl.908102.
JAMA
1.Lafçı G. A novel bileaflet sparing technique during mitral valve replacement: Lafci’s fold down technique. TJCL. 2021;12:123–126.
MLA
Lafçı, Gökhan. “A novel bileaflet sparing technique during mitral valve replacement: Lafci’s fold down technique”. Turkish Journal of Clinics and Laboratory, c. 12, sy 2, Haziran 2021, ss. 123-6, doi:10.18663/tjcl.908102.
Vancouver
1.Gökhan Lafçı. A novel bileaflet sparing technique during mitral valve replacement: Lafci’s fold down technique. TJCL. 01 Haziran 2021;12(2):123-6. doi:10.18663/tjcl.908102

e-ISSN: 2149-8296

Publication Model: Continuous Publication

Peer Review Model: Double-Blind Peer Review

Publication Language: Turkish and English

Access Model: Open Access

DOI Prefix: (Crossref DOI numaranız)

Publisher: DNT Ortadoğu Publishing Inc.

Journal Abbreviation: Turk J Clin Lab

Indexed in J-Gate

The content of this site is intended for health care professionals. All the published articles are distributed under the terms of

Creative Commons Attribution Licence,

which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.