Göğüs İncelemelerinde Farklı Tüp Voltajının Tüm Vücut Dozu ve Görüntü Kalitesine Etkisinin Termolüminesans Dozimetrelerle Değerlendirilmesi
Abstract
Keywords
References
- [1] IPEM, 2003. Measurement of the performance characteristics of diagnostic X-ray system used in medicine, Part 3, Computed tomography scanners, 2nd edition. Institution of Physics and Engineering in Medicine, New York, Report No:32.
- [2] Bacher, K. 2006. Evaluation of image quality and patient radiation dose in digital radiology. Doctoral thesis. Ghent University, p.140, Belgium.
- [3] Moore, C.S., Wood, T.J., Beavis, A.W., Saunderson, J.R. 2013. Correletion of the clinical and physical image quality in chest radiography for average adults with a computed radiography imaging system. British Journal of Radiology, 86, 0077.
- [4] Tinberg, A., Sjöström, D. 2003. Search for optimal tube voltage for image plate radiography. Conference Paper in Proceedings of SPIE- The International Society for Optical Engineering.
- [5] Uffmann, M., Neitzel, U., Prokop, M., Kabalan, N., Weber, M.,Herold, C.J. 2005. Flat-panel-dedector chest radiography: effect of tube voltage on image quality. Radiology, 235;642-650.
- [6] Yavuz, D,. 2020. Dijital radyografideki göğüs incelemelerinde farklı Tüp voltajının tüm vücut dozu ve görüntü kaltesine etkisinin araştırılması. Yüksek Lisans Tezi, Ankara üniversitesi Nükleer Bilimler Enstitüsü. Ankara.
- [7] Fernandez, S., Garcia-Salcedo, R., Mendoza, J.G., Sanchez-Guzman, D., Rodrigez, G.R., Gaona, E., Montalvo, T.R. 2016. Thermolüminescent characteristics of Lif:Mg,Cu,P and CaSO4:Dy for low dose measurement. Applied Radiation and Isotopes, 111, 50-55.
- [8] Sina, S., Zeinali, B., Karimipourfard, R.M., Lotfalizadeh, F., Sadeghi, M., Zamani, E., Zehtabian, M., Faghihi, R. 2014. Comparison of the response of TLD-100 and TLD-100H dosimeters in diagnostic radiology. World Academy of Science Engineering and Technology Biomedical and Biological Engineering, Vol: 1, No:9.
Details
Primary Language
Turkish
Subjects
Engineering
Journal Section
Research Article
Authors
Duygu Yavuz
*
0000-0003-2075-6617
Türkiye
Eren Şahiner
0000-0002-7159-2491
Türkiye
Engin Aşlar
0000-0002-1414-0317
Türkiye
Niyazi Meriç
0000-0003-1562-1312
Türkiye
Publication Date
December 30, 2021
Submission Date
January 20, 2021
Acceptance Date
November 7, 2021
Published in Issue
Year 2021 Volume: 25 Number: 3
Cited By
Göğüs İncelemelerinde Farklı Tüp Voltajının Tüm Vücut Dozu ve Görüntü Kalitesine Etkisinin Termolüminesans Dozimetrelerle Değerlendirilmesi
Süleyman Demirel Üniversitesi Fen Bilimleri Enstitüsü Dergisi
https://doi.org/10.19113/sdufenbed.860196