BibTex RIS Kaynak Göster

LC/MS Combined with High-Field Asymmetric Wave Ion Mobility Spectrometer FAIMS and its Applications on Food Analysis.

Yıl 2013, Cilt: 11 Sayı: 3-4, 96 - 100, 01.09.2013

Öz

Ion mobility spectrometry IMS is an ion separation technique used to separate ionized molecules in the gas phase based on their mobility in a carrier gas. IMS significantly improves the identification capabilities of mass spectrometric analysis methods. High-Field Asymmetric Waveform Ion Mobility Spectrometry FAIMS is a new variation of ion mobility spectrometry. It is used under atmospheric pressure conditions and room temperature. The most important feature of the ion-mobility spectrometry method is the capability for gas-phase ion separation prior to mass spectrometry analysis. It is located between the ion source and the mass spectrometer. FAIMS when combined with mass spectrometry offers value-added data not possible from mass spectra alone. FAIMS combined with liquid chromatography-tandem mass spectrometry device provides separation of isomeric and isobaric analytes, reduces chemical noise, eliminates matrix interferences and improves signal-to-noise S/N ratio by selective ion transmission

Kaynakça

  • Giray, H., Soysal, A., 2007. Türkiye’de Gıda Güvenliği ve Mevzuatı. TSK Koruyucu Hekimlik Bülteni 6 (6): 485- 490.
  • Nielen, M.W.F., Marvin, H.J.P., 2008. Challenges in Chemical Food Contaminants and Residue Analysis. Comprehensive Analytical Chemistry, Edited by D. Barcelo, Elsevier, 525 B Street, Suite 1900 San Diego, CA 92101-4495, USA, 848p.
  • Howdle, M.D., Eckers, C., Laures, A.M.F., Creaser, C.S., 2009. The use of shift reagents in ion mobility- mass spectrometry: studies on the complexation of an polyethylene glycol excipients. Journal of the American Society for Mass Spectrometry 20: 1-9.
  • Miller, R.A., Eiceman, G.A., Nazarov, E.G., King, T.A., 2000. A novel micromachined high-field asymmetric waveform-ion mobility spectrometer. Sensors and Actuators B 67: 300–306.
  • Ewing, R.G., Atkinson, D.A., Eiceman, G.A., Ewing, G.J., 2001. A critical review of ion mobility spectrometry for the detection of explosives and explosive related compounds. Talanta 54: 515–529.
  • Jafari, M.T., Rezaei, B., Javaheri, M., 2011. A new method based on electrospray ionisation ion mobility spectrometry (ESI-IMS) for simultaneous determination of caffeine and theophylline. Food Chemistry 126: 1964–1970.
  • Borsdorf, H., Neitsch, K., Eiceman, G.A., Stone, J.A., 2009. A comparison of the ion chemistry for mono-substituted toluenes and anilines by three methods of atmospheric pressure ionization with ion mobility spectrometry. Talanta 78: 1464–1475.
  • Armenta, S., Alcala, M., Blanco, M., 2011. A review of recent, unconventional applications of ion mobility spectrometry (IMS). Analytica Chimica Acta 703: 114– 123.
  • Debono, R., 2002. Ion Mobility Spectrometry: A Fast, Sensitive and Robust HPLC Alternative. Applications in Chromatography 2002: 20-23.
  • Xia, Y.Q., Wu, S.T., Jemal, M., 2008. LC-FAIMS- MS/MS for quantification of a peptide in plasma and evaluation of FAIMS global selectivity from plasma components. Analytical Chemistry 80: 7137-7143.
  • Borsdorf, H., Eiceman, G.A., 2006. Ion mobility spectrometry: principles and applications. Applied Spectroscopy Reviews 41: 323-375.
  • Tabrizchi, M., Abedi, A., 2002. A novel electron source for negative ion mobility spectrometry. International Journal of Mass Spectrometry 218: 75–85.
  • Miller, R.A., Nazarov, E.G., Eiceman, G.A., King, T.A., 2001. A MEMS radio- frequency ion mobility spectrometer for chemical vapor detection. Sensors and Actuators A 91: 301-312.
  • Canterburg, J.D., Gladden, J., Buck, L., Olund, R., Maccoss, M.J., 2010. A high voltage asymmetric waveform generator for FAIMS. Journal of the American Society for Mass Spectrometry 21: 1118- 1121.
  • O’Donnel, R.M., Sun, X., Harrington, R.B., 2008. Pharmaceutical applications of ion mobility spectrometry. Trends in Analytical Chemistry 27(1): 44- 53.
  • Anonymous, 2007a. FAIMS Operator’s Manual. Thermo Fisher Scientific Inc. 122 p. USA.
  • Chilai, C., Cong, Z., Deyi, K., Tao, M., Xinhua, L., 2011. A study on using a micro differential mobility spectrometry separation and detection. Energy Procedia 13: 4975- 4980. for toluidine ısomers
  • Rorrer III, L.C., Yost, R.A., 2011. Solvent vapor effects on planar high-field asymmetric waveform ion mobility spectrometry. International Journal of Mass Spectrometry 300: 173–181.
  • Purves, R.W., Barnett, D.A., Guevroment, R., 2000. Separation electrospray-high field asymmetric waveform ion mobility International Journal of Mass Spectrometry 197: 163–177. conformers using spectrometry-mass spectrometry.
  • Guevroment, R., 2004. High-field asymmetric waveform ion mobility spectrometry: A new tool for mass spectrometry. Journal of Chromatography A 1058: 3–19.
  • Anonymous, 2007b. FAIMS on the TSQ quantum: Tuning for selective quantitation quick reference guide. Thermo Fisher Scientific Inc. USA.
  • Hajslova, J., Zrostlikova, J., 2003. Matrix effects in (ultra) trace analysis of pesticide residues in food and biotic matrices. Journal of Chromatography A 1000: 181–197.
  • Mccooeye, M., Kolakowski, B., Boison, J., Mester, Z., 2008. Evaluation of high-field asymmetric waveform ion mobility spectrometry mass spectrometry for the analysis of the mycotoxin zearalenone. Analytica Chimica Acta 627: 112–116.
  • Cui, M., Ding, L., Mester, Z., 2003. Separation of cisplatin and its hydrolysis products using electrospray ionization high-field asymmetric waveform ion mobility spectrometry coupled with ion trap mass spectrometry. Analytical Chemistry 75: 5847-5853.
  • Kelavkar, U., Hutzley, J., Mcnally, J., 2007. Chemical Determination of Linoleic Acid Using LC-FAIMS- MS. Thermo Application Note: 400, Thermo Fisher Scientific Inc. USA. Removal in the
  • Nakagawa, K., 2008. Enhanced LC-MS/MS Selectivity for the Analysis of Human Urinary 8- isoprostane, using FAIMS. Thermo Application Note: 431, Thermo Fisher Scientific Inc. USA.
  • Klassen, T., Roemer, A., 2008. LC-FAIMS-MS Validated Quantitation Method for a Peptide in Rat Serum. Thermo Application Note: 448, Thermo Fisher Scientific Inc. USA.
  • Yıldız, G., 2012. İyon hareketliliği spektrometresi ile birleştirilmiş LC-MSMS cihazı kullanılarak bazı sebzelerde pestisit kalıntılarının belirlenmesi. Yüksek Lisans Tezi, Akdeniz Üniversitesi, 125s.

LC/MS ile Birleştirilmiş Yüksek Alan Asimetrik Dalga İyon Hareketliliği Spektrometresi FAIMS ve Gıda Analizlerinde Kullanımı

Yıl 2013, Cilt: 11 Sayı: 3-4, 96 - 100, 01.09.2013

Öz

İyon hareketliliği spektrometresi IMS , bir taşıyıcı gaz içinde hareket eden iyonların ayırımını sağlayan bir iyon ayırma tekniğidir. IMS tekniği kütle spektrometresi ile yapılan analizlerin belirleme yeteneğini önemli ölçüde geliştirmektedir. Yüksek Alan Asimetrik Dalga İyon Hareketliliği Spektrometresi FAIMS yeni bir iyon hareketliliği spektrometresi tekniğidir. FAIMS atmosferik basınç koşullarında ve oda sıcaklığında kullanılmaktadır. Bu tekniğin en önemli özelliği kütle spektrometresi ile yapılacak analizden önce gaz fazında iyonların ayırımının sağlanmasıdır. Cihaz iyon kaynağı ile kütle spektrometresi arasına yerleştirilmektedir. Kütle spektrometresi cihazlarının FAIMS ile birleştirilmesi bazı ek avantajlar sağlamaktadır. Sıvı kromatografisi-tandem kütle spektrometresi LC-MSMS ile birleştirilmiş FAIMS cihazı, izomerik ve izobarik analitlerin ayrımını sağlamakta, kimyasal gürültüyü azaltmakta, matriks etkisini gidermekte ve sinyal/gürültü S/N oranını artırmaktadır

Kaynakça

  • Giray, H., Soysal, A., 2007. Türkiye’de Gıda Güvenliği ve Mevzuatı. TSK Koruyucu Hekimlik Bülteni 6 (6): 485- 490.
  • Nielen, M.W.F., Marvin, H.J.P., 2008. Challenges in Chemical Food Contaminants and Residue Analysis. Comprehensive Analytical Chemistry, Edited by D. Barcelo, Elsevier, 525 B Street, Suite 1900 San Diego, CA 92101-4495, USA, 848p.
  • Howdle, M.D., Eckers, C., Laures, A.M.F., Creaser, C.S., 2009. The use of shift reagents in ion mobility- mass spectrometry: studies on the complexation of an polyethylene glycol excipients. Journal of the American Society for Mass Spectrometry 20: 1-9.
  • Miller, R.A., Eiceman, G.A., Nazarov, E.G., King, T.A., 2000. A novel micromachined high-field asymmetric waveform-ion mobility spectrometer. Sensors and Actuators B 67: 300–306.
  • Ewing, R.G., Atkinson, D.A., Eiceman, G.A., Ewing, G.J., 2001. A critical review of ion mobility spectrometry for the detection of explosives and explosive related compounds. Talanta 54: 515–529.
  • Jafari, M.T., Rezaei, B., Javaheri, M., 2011. A new method based on electrospray ionisation ion mobility spectrometry (ESI-IMS) for simultaneous determination of caffeine and theophylline. Food Chemistry 126: 1964–1970.
  • Borsdorf, H., Neitsch, K., Eiceman, G.A., Stone, J.A., 2009. A comparison of the ion chemistry for mono-substituted toluenes and anilines by three methods of atmospheric pressure ionization with ion mobility spectrometry. Talanta 78: 1464–1475.
  • Armenta, S., Alcala, M., Blanco, M., 2011. A review of recent, unconventional applications of ion mobility spectrometry (IMS). Analytica Chimica Acta 703: 114– 123.
  • Debono, R., 2002. Ion Mobility Spectrometry: A Fast, Sensitive and Robust HPLC Alternative. Applications in Chromatography 2002: 20-23.
  • Xia, Y.Q., Wu, S.T., Jemal, M., 2008. LC-FAIMS- MS/MS for quantification of a peptide in plasma and evaluation of FAIMS global selectivity from plasma components. Analytical Chemistry 80: 7137-7143.
  • Borsdorf, H., Eiceman, G.A., 2006. Ion mobility spectrometry: principles and applications. Applied Spectroscopy Reviews 41: 323-375.
  • Tabrizchi, M., Abedi, A., 2002. A novel electron source for negative ion mobility spectrometry. International Journal of Mass Spectrometry 218: 75–85.
  • Miller, R.A., Nazarov, E.G., Eiceman, G.A., King, T.A., 2001. A MEMS radio- frequency ion mobility spectrometer for chemical vapor detection. Sensors and Actuators A 91: 301-312.
  • Canterburg, J.D., Gladden, J., Buck, L., Olund, R., Maccoss, M.J., 2010. A high voltage asymmetric waveform generator for FAIMS. Journal of the American Society for Mass Spectrometry 21: 1118- 1121.
  • O’Donnel, R.M., Sun, X., Harrington, R.B., 2008. Pharmaceutical applications of ion mobility spectrometry. Trends in Analytical Chemistry 27(1): 44- 53.
  • Anonymous, 2007a. FAIMS Operator’s Manual. Thermo Fisher Scientific Inc. 122 p. USA.
  • Chilai, C., Cong, Z., Deyi, K., Tao, M., Xinhua, L., 2011. A study on using a micro differential mobility spectrometry separation and detection. Energy Procedia 13: 4975- 4980. for toluidine ısomers
  • Rorrer III, L.C., Yost, R.A., 2011. Solvent vapor effects on planar high-field asymmetric waveform ion mobility spectrometry. International Journal of Mass Spectrometry 300: 173–181.
  • Purves, R.W., Barnett, D.A., Guevroment, R., 2000. Separation electrospray-high field asymmetric waveform ion mobility International Journal of Mass Spectrometry 197: 163–177. conformers using spectrometry-mass spectrometry.
  • Guevroment, R., 2004. High-field asymmetric waveform ion mobility spectrometry: A new tool for mass spectrometry. Journal of Chromatography A 1058: 3–19.
  • Anonymous, 2007b. FAIMS on the TSQ quantum: Tuning for selective quantitation quick reference guide. Thermo Fisher Scientific Inc. USA.
  • Hajslova, J., Zrostlikova, J., 2003. Matrix effects in (ultra) trace analysis of pesticide residues in food and biotic matrices. Journal of Chromatography A 1000: 181–197.
  • Mccooeye, M., Kolakowski, B., Boison, J., Mester, Z., 2008. Evaluation of high-field asymmetric waveform ion mobility spectrometry mass spectrometry for the analysis of the mycotoxin zearalenone. Analytica Chimica Acta 627: 112–116.
  • Cui, M., Ding, L., Mester, Z., 2003. Separation of cisplatin and its hydrolysis products using electrospray ionization high-field asymmetric waveform ion mobility spectrometry coupled with ion trap mass spectrometry. Analytical Chemistry 75: 5847-5853.
  • Kelavkar, U., Hutzley, J., Mcnally, J., 2007. Chemical Determination of Linoleic Acid Using LC-FAIMS- MS. Thermo Application Note: 400, Thermo Fisher Scientific Inc. USA. Removal in the
  • Nakagawa, K., 2008. Enhanced LC-MS/MS Selectivity for the Analysis of Human Urinary 8- isoprostane, using FAIMS. Thermo Application Note: 431, Thermo Fisher Scientific Inc. USA.
  • Klassen, T., Roemer, A., 2008. LC-FAIMS-MS Validated Quantitation Method for a Peptide in Rat Serum. Thermo Application Note: 448, Thermo Fisher Scientific Inc. USA.
  • Yıldız, G., 2012. İyon hareketliliği spektrometresi ile birleştirilmiş LC-MSMS cihazı kullanılarak bazı sebzelerde pestisit kalıntılarının belirlenmesi. Yüksek Lisans Tezi, Akdeniz Üniversitesi, 125s.
Toplam 28 adet kaynakça vardır.

Ayrıntılar

Birincil Dil Türkçe
Bölüm Research Article
Yazarlar

Bülent Şık Bu kişi benim

Gizem Yıldız Bu kişi benim

Taner Erkaymaz Bu kişi benim

Timur Tongur Bu kişi benim

Yayımlanma Tarihi 1 Eylül 2013
Yayımlandığı Sayı Yıl 2013 Cilt: 11 Sayı: 3-4

Kaynak Göster

APA Şık, B., Yıldız, G., Erkaymaz, T., Tongur, T. (2013). LC/MS ile Birleştirilmiş Yüksek Alan Asimetrik Dalga İyon Hareketliliği Spektrometresi FAIMS ve Gıda Analizlerinde Kullanımı. Akademik Gıda, 11(3-4), 96-100.
AMA Şık B, Yıldız G, Erkaymaz T, Tongur T. LC/MS ile Birleştirilmiş Yüksek Alan Asimetrik Dalga İyon Hareketliliği Spektrometresi FAIMS ve Gıda Analizlerinde Kullanımı. Akademik Gıda. Eylül 2013;11(3-4):96-100.
Chicago Şık, Bülent, Gizem Yıldız, Taner Erkaymaz, ve Timur Tongur. “LC/MS Ile Birleştirilmiş Yüksek Alan Asimetrik Dalga İyon Hareketliliği Spektrometresi FAIMS Ve Gıda Analizlerinde Kullanımı”. Akademik Gıda 11, sy. 3-4 (Eylül 2013): 96-100.
EndNote Şık B, Yıldız G, Erkaymaz T, Tongur T (01 Eylül 2013) LC/MS ile Birleştirilmiş Yüksek Alan Asimetrik Dalga İyon Hareketliliği Spektrometresi FAIMS ve Gıda Analizlerinde Kullanımı. Akademik Gıda 11 3-4 96–100.
IEEE B. Şık, G. Yıldız, T. Erkaymaz, ve T. Tongur, “LC/MS ile Birleştirilmiş Yüksek Alan Asimetrik Dalga İyon Hareketliliği Spektrometresi FAIMS ve Gıda Analizlerinde Kullanımı”, Akademik Gıda, c. 11, sy. 3-4, ss. 96–100, 2013.
ISNAD Şık, Bülent vd. “LC/MS Ile Birleştirilmiş Yüksek Alan Asimetrik Dalga İyon Hareketliliği Spektrometresi FAIMS Ve Gıda Analizlerinde Kullanımı”. Akademik Gıda 11/3-4 (Eylül 2013), 96-100.
JAMA Şık B, Yıldız G, Erkaymaz T, Tongur T. LC/MS ile Birleştirilmiş Yüksek Alan Asimetrik Dalga İyon Hareketliliği Spektrometresi FAIMS ve Gıda Analizlerinde Kullanımı. Akademik Gıda. 2013;11:96–100.
MLA Şık, Bülent vd. “LC/MS Ile Birleştirilmiş Yüksek Alan Asimetrik Dalga İyon Hareketliliği Spektrometresi FAIMS Ve Gıda Analizlerinde Kullanımı”. Akademik Gıda, c. 11, sy. 3-4, 2013, ss. 96-100.
Vancouver Şık B, Yıldız G, Erkaymaz T, Tongur T. LC/MS ile Birleştirilmiş Yüksek Alan Asimetrik Dalga İyon Hareketliliği Spektrometresi FAIMS ve Gıda Analizlerinde Kullanımı. Akademik Gıda. 2013;11(3-4):96-100.

25964   25965    25966      25968   25967


88x31.png

Bu eser Creative Commons Atıf-GayriTicari 4.0 (CC BY-NC 4.0) Uluslararası Lisansı ile lisanslanmıştır.

Akademik Gıda (Academic Food Journal) is licensed under a Creative Commons Attribution-NonCommercial 4.0 International (CC BY-NC 4.0).