EN
Simultaneous Resolution of Overlapping Tailing Peaks of Isomers Using Dual Detector Diode Array Liquid Chromatography Electrospray Mass Spectrometry
Öz
It is now common to obtain information from two or more detectors in HPLC simultaneously. Conventionally both DAD-HPLC and LC-MS data are obtained independently, often using quite different approaches, but there will be common features in both types of information. However, these will be distorted, for example, Electrospray MS profiles are typically more noisy and tailing compared to those from DAD-HPLC due to the different physical processes of passing from the chromatographic column to the detector. A method for obtaining and processing both types of data simultaneously is described. The analysis of isomers with identical molecular weights and similar elution times is particularly important in the pharmaceutical industry where small impurities can have a major influence on biological activity. The approach is illustrated by application to a mixture of 2- and 3-hydroxypyridine at varying levels of overlap
Ayrıntılar
Birincil Dil
Türkçe
Konular
-
Bölüm
-
Yayımlanma Tarihi
1 Haziran 2001
Gönderilme Tarihi
1 Haziran 2001
Kabul Tarihi
-
Yayımlandığı Sayı
Yıl 2001 Cilt: 3 Sayı: 1
APA
Brereton, R. G., & Bessant, C. (2001). Simultaneous Resolution of Overlapping Tailing Peaks of Isomers Using Dual Detector Diode Array Liquid Chromatography Electrospray Mass Spectrometry. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi, 3(1), 148-174. https://izlik.org/JA23TE36YW
AMA
1.Brereton RG, Bessant C. Simultaneous Resolution of Overlapping Tailing Peaks of Isomers Using Dual Detector Diode Array Liquid Chromatography Electrospray Mass Spectrometry. BAUN Fen. Bil. Enst. Dergisi. 2001;3(1):148-174. https://izlik.org/JA23TE36YW
Chicago
Brereton, Rivhard G., ve Conrad Bessant. 2001. “Simultaneous Resolution of Overlapping Tailing Peaks of Isomers Using Dual Detector Diode Array Liquid Chromatography Electrospray Mass Spectrometry”. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi 3 (1): 148-74. https://izlik.org/JA23TE36YW.
EndNote
Brereton RG, Bessant C (01 Haziran 2001) Simultaneous Resolution of Overlapping Tailing Peaks of Isomers Using Dual Detector Diode Array Liquid Chromatography Electrospray Mass Spectrometry. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi 3 1 148–174.
IEEE
[1]R. G. Brereton ve C. Bessant, “Simultaneous Resolution of Overlapping Tailing Peaks of Isomers Using Dual Detector Diode Array Liquid Chromatography Electrospray Mass Spectrometry”, BAUN Fen. Bil. Enst. Dergisi, c. 3, sy 1, ss. 148–174, Haz. 2001, [çevrimiçi]. Erişim adresi: https://izlik.org/JA23TE36YW
ISNAD
Brereton, Rivhard G. - Bessant, Conrad. “Simultaneous Resolution of Overlapping Tailing Peaks of Isomers Using Dual Detector Diode Array Liquid Chromatography Electrospray Mass Spectrometry”. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi 3/1 (01 Haziran 2001): 148-174. https://izlik.org/JA23TE36YW.
JAMA
1.Brereton RG, Bessant C. Simultaneous Resolution of Overlapping Tailing Peaks of Isomers Using Dual Detector Diode Array Liquid Chromatography Electrospray Mass Spectrometry. BAUN Fen. Bil. Enst. Dergisi. 2001;3:148–174.
MLA
Brereton, Rivhard G., ve Conrad Bessant. “Simultaneous Resolution of Overlapping Tailing Peaks of Isomers Using Dual Detector Diode Array Liquid Chromatography Electrospray Mass Spectrometry”. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi, c. 3, sy 1, Haziran 2001, ss. 148-74, https://izlik.org/JA23TE36YW.
Vancouver
1.Rivhard G. Brereton, Conrad Bessant. Simultaneous Resolution of Overlapping Tailing Peaks of Isomers Using Dual Detector Diode Array Liquid Chromatography Electrospray Mass Spectrometry. BAUN Fen. Bil. Enst. Dergisi [Internet]. 01 Haziran 2001;3(1):148-74. Erişim adresi: https://izlik.org/JA23TE36YW