The Effect of the Barrier Mounted on the Kitchen Hood Suitable for Central Ventilation Systems on the Odour Extraction Performance

Öz

In this study, the effects of the barrier added to the kitchen hood suitable for central ventilation systems on the performance of odour extraction are investigated. For this purpose, the hood used in the kitchens of the buildings with central ventilation systems has been selected. Taguchi L18 (61x31) experimental design method was used to optimize the odour extraction performance of the hood and to examine it both experimentally and statistically. Kitchen hoods with different size barriers have been created with the selected method. The experiments were conducted in the test room in accordance with international standards. When the results of the experiment were examined, it was observed that the odour extraction performance of the hoods created in the experiments was the best 97.1% and the worst was 69.4%. When the signal/noise ratios of the experiments carried out with different size barrier and flow parameters were examined, the most ideal levels for C2 were determined as A6B3. When the Anova results were examined, it is determined that the most effective parameter for C2 was barrier (cm) with 76.01% and flow rate (m3/h) with 21.24%. By means of the barrier added to the hood, higher odour extraction performance has provided.

Anahtar Kelimeler

Teşekkür

Thanks to Silverline Endüstri A.Ş. and its employees for their support, and also to R&D director Semra ASLAN for their support.

Kaynakça

  1. Liddament, M. (1996). A Guide to Energy Efficient Ventilation, Air Infiltration and Ventilation Centre, Sint-Stevens-Woluwe. Belgium, 85, 9.
  2. Concannon, P. (2002). Technical Note AIVC 57: Residential Ventilation. Air Infiltration and Ventilation Center, Brussels.
  3. Schild, P. G. (2007). State-of-the-art of low-energy residential ventilation. Contributed Report 7.
  4. Lundbäck, B. (1998). Epidemiology of rhinitis and asthma. Clinical and experimental allergy: journal of the British Society for Allergy and Clinical Immunology, 28, 3-10.
  5. Heinrich, J. (2011). Influence of indoor factors in dwellings on the development of childhood asthma. International journal of hygiene and environmental health, 214.1, 1-25.
  6. Jacobs, P., Cornelissen, E. & Borsboom, W. (2016). Energy efficient measures to reduce PM2, 5 emissions due to cooking. Indoor Air conference, TNO, Delft, Netherlands.
  7. Stratton, J.C. & Singer, B.C. (2014). Addressing Kitchen Contaminants for Healthy. Low-energy Homes.
  8. Abdullahi, K.L., Delgado-Saborit, J.M. & Harrison, R.M. (2013). Emissions and indoor concentrations of particulate matter and its specific chemical components from cooking: a review. Atmospheric Environment. 71, 260–294.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mühendislik

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

30 Aralık 2020

Gönderilme Tarihi

29 Nisan 2020

Kabul Tarihi

7 Eylül 2020

Yayımlandığı Sayı

Yıl 2020 Cilt: 7 Sayı: 2

Kaynak Göster

APA
Özbakış, Y., Erzincanlı, F., Nas, E., & Çeviksever, T. (2020). The Effect of the Barrier Mounted on the Kitchen Hood Suitable for Central Ventilation Systems on the Odour Extraction Performance. Bilecik Şeyh Edebali Üniversitesi Fen Bilimleri Dergisi, 7(2), 1015-1025. https://doi.org/10.35193/bseufbd.729087
AMA
1.Özbakış Y, Erzincanlı F, Nas E, Çeviksever T. The Effect of the Barrier Mounted on the Kitchen Hood Suitable for Central Ventilation Systems on the Odour Extraction Performance. Bilecik Şeyh Edebali Üniversitesi Fen Bilimleri Dergisi. 2020;7(2):1015-1025. doi:10.35193/bseufbd.729087
Chicago
Özbakış, Yusuf, Fehmi Erzincanlı, Engin Nas, ve Tolga Çeviksever. 2020. “The Effect of the Barrier Mounted on the Kitchen Hood Suitable for Central Ventilation Systems on the Odour Extraction Performance”. Bilecik Şeyh Edebali Üniversitesi Fen Bilimleri Dergisi 7 (2): 1015-25. https://doi.org/10.35193/bseufbd.729087.
EndNote
Özbakış Y, Erzincanlı F, Nas E, Çeviksever T (01 Aralık 2020) The Effect of the Barrier Mounted on the Kitchen Hood Suitable for Central Ventilation Systems on the Odour Extraction Performance. Bilecik Şeyh Edebali Üniversitesi Fen Bilimleri Dergisi 7 2 1015–1025.
IEEE
[1]Y. Özbakış, F. Erzincanlı, E. Nas, ve T. Çeviksever, “The Effect of the Barrier Mounted on the Kitchen Hood Suitable for Central Ventilation Systems on the Odour Extraction Performance”, Bilecik Şeyh Edebali Üniversitesi Fen Bilimleri Dergisi, c. 7, sy 2, ss. 1015–1025, Ara. 2020, doi: 10.35193/bseufbd.729087.
ISNAD
Özbakış, Yusuf - Erzincanlı, Fehmi - Nas, Engin - Çeviksever, Tolga. “The Effect of the Barrier Mounted on the Kitchen Hood Suitable for Central Ventilation Systems on the Odour Extraction Performance”. Bilecik Şeyh Edebali Üniversitesi Fen Bilimleri Dergisi 7/2 (01 Aralık 2020): 1015-1025. https://doi.org/10.35193/bseufbd.729087.
JAMA
1.Özbakış Y, Erzincanlı F, Nas E, Çeviksever T. The Effect of the Barrier Mounted on the Kitchen Hood Suitable for Central Ventilation Systems on the Odour Extraction Performance. Bilecik Şeyh Edebali Üniversitesi Fen Bilimleri Dergisi. 2020;7:1015–1025.
MLA
Özbakış, Yusuf, vd. “The Effect of the Barrier Mounted on the Kitchen Hood Suitable for Central Ventilation Systems on the Odour Extraction Performance”. Bilecik Şeyh Edebali Üniversitesi Fen Bilimleri Dergisi, c. 7, sy 2, Aralık 2020, ss. 1015-2, doi:10.35193/bseufbd.729087.
Vancouver
1.Yusuf Özbakış, Fehmi Erzincanlı, Engin Nas, Tolga Çeviksever. The Effect of the Barrier Mounted on the Kitchen Hood Suitable for Central Ventilation Systems on the Odour Extraction Performance. Bilecik Şeyh Edebali Üniversitesi Fen Bilimleri Dergisi. 01 Aralık 2020;7(2):1015-2. doi:10.35193/bseufbd.729087

Cited By