X-IŞINI GÖRÜNTÜLEMEDE YARIİLETKEN DEDEKTÖRLERİN KULLANILMASI

Cilt: 4 Sayı: 2 1 Mayıs 2002
  • Sevil Bayburt
  • Mehmet Bayburt
PDF İndir
EN TR

USING SEMICONDUCTOR DETECTORS IN X-RAY IMAGE

Öz

Different detectors are being used in X-ray imaging. They can be classified as scintillation and semiconductor detectors. In this study CsI and CdTe type detectors, which are especially used today in angiography, have been compared. First, these detectors have been simulated in computer and experiments have been carried out by applying two different tube techniques, which are usually used in angiography with an X-ray simulation program. In this technique, firstly, low voltage (60 kVp) is applied to the tube with a copper sheet in front of it that serves as an inherent filter. Then, higher voltage (120kVp) is applied to the tube with a copper and aluminum sheets in front of the tube for the same purpose. Image is composed by evaluating different spectrums obtained. These experiments have been repeated for different values of applied voltages and different type ad thickness of inherent sheets. As a result of these experiments, it was found that the signal to noise ratio (SNR) of the CdTe type detector is found to be approximately ten times greater than the CsI type detectors that are used presently. From this profile, especially at X-rays monitoring field in the future, CdTe type detectors could be used extensively at low energies.

Anahtar Kelimeler

Kaynakça

  1. Molloi S.Y., Mistretta C.A. (1989): “Quantification Techniques for Dual-Energy Cardiac Imaging”, Med.Phys., 16(2), 209-217.
  2. Molloi S., Ersahin A., Qian Y. (1995): “CCD Camera for Dual-Energy Digital Subtraction Angiography”, IEEE Trans. Med. Imag., V. 14 N. 4, p. 747-752.
  3. Nalcioglu O., Lou R.Y. (1979): “Post-Reconstruction Method for Beam Hardening in Computerised Tomograghy”, Phys. Med. Biol., V. 24, N.2, p.330-340.
  4. Scheiber C. (1996): “New Developments in Clinical Applications of CdTe and CdZnTe Detectors”, Nucl. Instr. and Meth. in Phys., Res. A380, p. 385-391.
  5. Amp-Tek (1998): “X-ray and Gamma Ray Detector High Resolution CZT Cadmium Zinc Telluride”.
  6. Nalcioglu O., Roeck W.W., Seibert J.A., Lando A.V., Tobis J.M., Henry W.L. (1986): “Qantitative Aspects of Image Intensifier-Television Based Digital X-ray Imaging”, in Digital Radiography: Selected Topics, edited by J.Kereiakes, S. R.Thomas and E. G.Orton (Plenum, New York).
  7. Interim Progress Report (7/1/75–3/1/76) for N.C.I. contract number NO1-CB-53914; M. P. Siedband, Principal Investigator.
  8. Progress Report (7/1/75–8/3/76) for N.C.I. contract number NO1-CB-53914; M.P. Siedband, Principal Investigator.

Ayrıntılar

Birincil Dil

Türkçe

Konular

-

Bölüm

-

Yazarlar

Sevil Bayburt Bu kişi benim

Mehmet Bayburt Bu kişi benim

Yayımlanma Tarihi

1 Mayıs 2002

Gönderilme Tarihi

1 Mayıs 2002

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2002 Cilt: 4 Sayı: 2

Kaynak Göster

APA
Bayburt, S., & Bayburt, M. (2002). X-IŞINI GÖRÜNTÜLEMEDE YARIİLETKEN DEDEKTÖRLERİN KULLANILMASI. Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi, 4(2), 113-122. https://izlik.org/JA32AY79MD
AMA
1.Bayburt S, Bayburt M. X-IŞINI GÖRÜNTÜLEMEDE YARIİLETKEN DEDEKTÖRLERİN KULLANILMASI. DEUFMD. 2002;4(2):113-122. https://izlik.org/JA32AY79MD
Chicago
Bayburt, Sevil, ve Mehmet Bayburt. 2002. “X-IŞINI GÖRÜNTÜLEMEDE YARIİLETKEN DEDEKTÖRLERİN KULLANILMASI”. Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi 4 (2): 113-22. https://izlik.org/JA32AY79MD.
EndNote
Bayburt S, Bayburt M (01 Mayıs 2002) X-IŞINI GÖRÜNTÜLEMEDE YARIİLETKEN DEDEKTÖRLERİN KULLANILMASI. Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi 4 2 113–122.
IEEE
[1]S. Bayburt ve M. Bayburt, “X-IŞINI GÖRÜNTÜLEMEDE YARIİLETKEN DEDEKTÖRLERİN KULLANILMASI”, DEUFMD, c. 4, sy 2, ss. 113–122, May. 2002, [çevrimiçi]. Erişim adresi: https://izlik.org/JA32AY79MD
ISNAD
Bayburt, Sevil - Bayburt, Mehmet. “X-IŞINI GÖRÜNTÜLEMEDE YARIİLETKEN DEDEKTÖRLERİN KULLANILMASI”. Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi 4/2 (01 Mayıs 2002): 113-122. https://izlik.org/JA32AY79MD.
JAMA
1.Bayburt S, Bayburt M. X-IŞINI GÖRÜNTÜLEMEDE YARIİLETKEN DEDEKTÖRLERİN KULLANILMASI. DEUFMD. 2002;4:113–122.
MLA
Bayburt, Sevil, ve Mehmet Bayburt. “X-IŞINI GÖRÜNTÜLEMEDE YARIİLETKEN DEDEKTÖRLERİN KULLANILMASI”. Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi, c. 4, sy 2, Mayıs 2002, ss. 113-22, https://izlik.org/JA32AY79MD.
Vancouver
1.Sevil Bayburt, Mehmet Bayburt. X-IŞINI GÖRÜNTÜLEMEDE YARIİLETKEN DEDEKTÖRLERİN KULLANILMASI. DEUFMD [Internet]. 01 Mayıs 2002;4(2):113-22. Erişim adresi: https://izlik.org/JA32AY79MD

Bu dergi, Creative Commons Atıf-GayriTicari 4.0 Uluslararası Lisansı (CC BY-NC 4.0) altında lisanslanmıştır.

download?token=eyJhdXRoX3JvbGVzIjpbXSwiZW5kcG9pbnQiOiJmaWxlIiwicGF0aCI6IjliNTAvMDBjMi8xZmIxLzY5MjZmZDIyOGE1NzgyLjA3MzU5MTk2LnBuZyIsImV4cCI6MTc2NDE2OTE1Nywibm9uY2UiOiJhZDRmNjNlNzdhOWYwOWQ4YTNjNGVmNGIxOTFlZWViNyJ9.4Dxgc9mc-p4Tyti8NTU5pxEfGUWeuJud1fPWxu2mUy8