Thermal Performance Investigation of Plain Finned-Tube Evaporators Used in Household Refrigerator
Öz
In this study, thermal performance of plain finned-tube evaporators in household refrigerators are investigated numerically and experimentally. The design parameters affecting on the cooling capacity are determined as air flowrate, evaporator temperature, tube alignment, number of tubes and number of fins. In the initial stage, the effects of those parameters on the cooling capacities are simulated by CoilDesigner software. The number of experiments that are necessary to obtain correlations is determined by Minitab software. The experiments are carried out in a no-frost household refrigerator in the off-mode. At the end of each experiment, air side heat transfer coefficients are calculated to generate a Nusselt (Nu) correlation as a function of the mentioned design parameters. The generated correlation of the cooling capacity can predict 95% of the experimental results within a confidence range of 15%. The correlation of the cooling capacity is converted to the Nusselt number correlation which is found to be consistent with available data in literature. The experiments reveal that the cooling capacity is dominantly affected by the evaporator temperature followed by air flow rate, tube alignment, number of tubes and the number of fins.
Anahtar Kelimeler
Kaynakça
- [1] N. Kayansayan, “Heat transfer characterization of flat plain fins and round tube heat exchangers,”Experimental thermal and fluid science, vol. 6, no. 3, pp. 263–272, 1993.
- [2] H. Karatas, E. Dirik, and T. Derbentli, “An experimental study of air-side heat transfer and friction factor correlations on domestic refrigerator finned-tube evaporator coils,” International Refrigeration and Air Conditioning Conference, 1996.
- [3] C.-C. Wang and K.-Y. Chi, “Heat transfer and friction characteristics of plain fin-and-tube heat ex- changers, part i: new experimental data,” International Journal of Heat and Mass Transfer, vol. 43, no. 15, pp. 2681–2691, 2000.
- [4] C.-C. Wang, K.-Y. Chi, and C.-J. Chang, “Heat transfer and friction characteristics of plain fin-and- tube heat exchangers, part ii: Correlation,” International Journal of Heat and mass transfer, vol. 43, no. 15, pp. 2693–2700, 2000.
- [5] N. Kim, B. Youn, and R. Webb, “Air-side heat transfer and friction correlations for plain fin-and- tube heat exchangers with staggered tube arrangements,” Journal of heat transfer, vol. 121, no. 3, pp. 662–667, 1999.
- [6] T.-H. Lee, J.-S. Lee, S.-Y. Oh, M. Lee, and K. Lee, “Comparison of air-side heat transfer coefficients of several types of evaporators of household freezer/refrigerators,” International Refrigeration and Air Conditioning Conference, 2002.
- [7] J. R. Barbosa Jr, C. Melo, C. J. Hermes, and P. J. Waltrich, “A study of the air-side heat transfer and pressure drop characteristics of tube-fin no-frostevaporators,” Applied Energy, vol. 86, no. 9, pp. 1484– 1491, 2009.
- [8] C. Melo, R. O. Piucco, and P. O. Durate, “In-situ performance evaluation of no-frost evaporators,”International Refrigeration and Air Conditioning Conference, 2006.
Ayrıntılar
Birincil Dil
İngilizce
Konular
-
Bölüm
Araştırma Makalesi
Yazarlar
Omer Alp Atici
*
0000-0002-9494-8032
Türkiye
Sertaç Çadırcı
Bu kişi benim
Tolga Apaydın
Bu kişi benim
Yayımlanma Tarihi
15 Mayıs 2020
Gönderilme Tarihi
1 Eylül 2019
Kabul Tarihi
14 Ekim 2019
Yayımlandığı Sayı
Yıl 2020 Cilt: 22 Sayı: 65