Araştırma Makalesi

A Water Absorption Chamber Design for Cable Capacitance Measurement Tests

Cilt: 7 Sayı: 2 31 Aralık 2024
PDF İndir
TR EN

A Water Absorption Chamber Design for Cable Capacitance Measurement Tests

Öz

XLPO cables used in ships should be tested for water absorption. Test standards require the cables be submerged in a water absorption chamber and kept at 75 0C for 14 days. Once every 7 days, the cables within the chamber are tested by applying high voltage, and their capacitance, dissipation factor, stability factor, and relative Permittivity are measured. In this study, a water absorption chamber used in the experiments is designed using fiberglass material and controlled with an ENDA ET 4420 temperature controller. It is experimentally shown that the water absorption chamber performs well.

Anahtar Kelimeler

Destekleyen Kurum

Ünika Üniversal Kablo Sanayi ve Tic. A.Ş.

Proje Numarası

UPN -2402

Etik Beyan

This study has been supported through the project UPN -2402 funded by the research and development center of Ünika Üniversal Kablo Sanayi ve Tic. A.Ş. The researchers are thankful to Samet Sarı, Fatih Yerişenoglu, and Sedef Özcan for their assistance.

Teşekkür

This study has been supported through the project UPN -2402 funded by the research and development center of Ünika Üniversal Kablo Sanayi ve Tic. A.Ş. The researchers are thankful to Samet Sarı, Fatih Yerişenoglu, and Sedef Özcan for their assistance.

Kaynakça

  1. Moore, G. F. (Ed.) (1997). Electric cables handbook, Blackwell Science, UK.
  2. Thue, W. A. (Ed.) (2017). Electrical power cable engineering, CRC Press, Boca Raton.
  3. Tan, R. K., Önder, K., Yerişenoğlu, F., & Mutlu, R. (2023). Usage of an Excel spreadsheet for a thermal endurance test report. European Journal of Engineering and Applied Sciences, 6(2), 91-97.
  4. Yurtsever M., Öztaş A., & Mutlu, R. (2024). Assessing the relationship between color change and tensile strength in Thermoplastic Polyolefin outer sheaths of low-voltage power cables. Trakya University Journal of Engineering Sciences, 25(1), 11-19.
  5. Georgallis, G. (2021). Submarine cables. The global cable industry: materials, markets, products, Wiley Online Library.
  6. Worzyk, T., Submarine power cables: design, installation, repair, environmental aspects. Springer Science & Business Media, pp. 291-310. 2009.
  7. Karhan, M., Çakır, M. F., & Uğur, M. (2021). A new approach to the analysis of water treeing using feature extraction of vented type water tree images. Journal of Electrical Engineering & Technology, 16, 1241-1252.
  8. Karhan, M., Çakır, M. F., & Uğur, M. (2020). Analysis of electric field and potential distribution of experimental setup for initiating and growing vented type water trees using finite element method. Journal of Science and Arts, 20(3), 755-766.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Elektrik Devreleri ve Sistemleri, Süreç Kontrolü ve Simülasyonu

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

31 Aralık 2024

Gönderilme Tarihi

8 Aralık 2024

Kabul Tarihi

27 Aralık 2024

Yayımlandığı Sayı

Yıl 2024 Cilt: 7 Sayı: 2

Kaynak Göster

APA
Ulutay, E., Yurtsever, M., Öztaş, A., Akyol, U., & Mutlu, R. (2024). A Water Absorption Chamber Design for Cable Capacitance Measurement Tests. European Journal of Engineering and Applied Sciences, 7(2), 150-158. https://doi.org/10.55581/ejeas.1598086
AMA
1.Ulutay E, Yurtsever M, Öztaş A, Akyol U, Mutlu R. A Water Absorption Chamber Design for Cable Capacitance Measurement Tests. EJEAS. 2024;7(2):150-158. doi:10.55581/ejeas.1598086
Chicago
Ulutay, Ercan, Metin Yurtsever, Avşin Öztaş, Uğur Akyol, ve Reşat Mutlu. 2024. “A Water Absorption Chamber Design for Cable Capacitance Measurement Tests”. European Journal of Engineering and Applied Sciences 7 (2): 150-58. https://doi.org/10.55581/ejeas.1598086.
EndNote
Ulutay E, Yurtsever M, Öztaş A, Akyol U, Mutlu R (01 Aralık 2024) A Water Absorption Chamber Design for Cable Capacitance Measurement Tests. European Journal of Engineering and Applied Sciences 7 2 150–158.
IEEE
[1]E. Ulutay, M. Yurtsever, A. Öztaş, U. Akyol, ve R. Mutlu, “A Water Absorption Chamber Design for Cable Capacitance Measurement Tests”, EJEAS, c. 7, sy 2, ss. 150–158, Ara. 2024, doi: 10.55581/ejeas.1598086.
ISNAD
Ulutay, Ercan - Yurtsever, Metin - Öztaş, Avşin - Akyol, Uğur - Mutlu, Reşat. “A Water Absorption Chamber Design for Cable Capacitance Measurement Tests”. European Journal of Engineering and Applied Sciences 7/2 (01 Aralık 2024): 150-158. https://doi.org/10.55581/ejeas.1598086.
JAMA
1.Ulutay E, Yurtsever M, Öztaş A, Akyol U, Mutlu R. A Water Absorption Chamber Design for Cable Capacitance Measurement Tests. EJEAS. 2024;7:150–158.
MLA
Ulutay, Ercan, vd. “A Water Absorption Chamber Design for Cable Capacitance Measurement Tests”. European Journal of Engineering and Applied Sciences, c. 7, sy 2, Aralık 2024, ss. 150-8, doi:10.55581/ejeas.1598086.
Vancouver
1.Ercan Ulutay, Metin Yurtsever, Avşin Öztaş, Uğur Akyol, Reşat Mutlu. A Water Absorption Chamber Design for Cable Capacitance Measurement Tests. EJEAS. 01 Aralık 2024;7(2):150-8. doi:10.55581/ejeas.1598086