Araştırma Makalesi

Sulfate Removal from Water by Ion Exchange Method Using Purolite A200 Resin

Sayı: 34 31 Mart 2022
PDF İndir
TR EN

Sulfate Removal from Water by Ion Exchange Method Using Purolite A200 Resin

Abstract

In this study, sulfate removal by ion exchange method using Purolite A200 resin was investigated. In the study, the effect of resin amount, temperature, initial pH of the solution, initial sulfate concentration of the solution and mixing speed were selected as parameters. As a result, in sulfate removal; it was observed that the initial pH value was not very effective, but the temperature, initial sulfate concentration, mixing speed and resin amount were effective and the removal efficiency increased with the increase in the values of these parameters. The qm value was found as -0.381, while the Langmuir coefficient KL value was found as -0.227. For Freundlich isotherm, the Kf value was found to be 0.617, while the n coefficient value was found to be 0.705. These result was show that Langmuir isotherm was found to be a more suitable adsorption isotherm than Freundlich isotherm for this system.

Keywords

Kaynakça

  1. Bertolacini R. J. and Barney, J. E. (1958). Ultraviolet Spectrophotometric Determination of Sulfate, Chloride, and Fluoride with Chloranilic Acid, Anal. Chem., 30(2), 202–205.
  2. Duranoglu, D. (2012). Sulfate removal from wastewater by chemical precipitation method, Journal of Engineering and Natural Sciences, 212, 39–55.
  3. EPA, Health Effects from Exposure to High Levels of Sulfate in Drinking Water Study. Environmental Protection, January 25th 1999.
  4. Guimarães, D. & Leão, V. A. (2014). Batch and fixed-bed assessment of sulphate removal by the weak base ion exchange resin Amberlyst A21, Journal of Hazardous Materials, 280, 209–215.
  5. MacKeown, H. Gyamfi, J. A. Delaporte, M. Schoutteten, K. V. K. M. Verdickt, L. Ouddane, B. & Criquet, J. (2021). Removal of disinfection by-product precursors by ion exchange resins, Journal of Environmental Chemical Engineering, 9(1), 104602.
  6. Öztürk, Y. & Ekmekçi, Z. (2020). Removal of sulfate ions from process water by ion exchange resins, Minerals Engineering, 159, 106613.
  7. Prolite A200 (2022) The Prolite website. Available: https://www.purolite.com/product/a200/
  8. Schubert, S. A. Clayton, J. W. and Fernando, Q. (1979). Determination of sulfite and sulfate in solids by time-resolved molecular emission spectrometry, Anal. Chem., 51(8), 1297–1301.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mühendislik

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

31 Mart 2022

Gönderilme Tarihi

1 Mart 2022

Kabul Tarihi

2 Mart 2022

Yayımlandığı Sayı

Yıl 2022 Sayı: 34

Kaynak Göster

APA
Akın, M. B., Hoşafcıoğlu Kıyısin, Z., & Kocakerim, M. M. (2022). Sulfate Removal from Water by Ion Exchange Method Using Purolite A200 Resin. Avrupa Bilim ve Teknoloji Dergisi, 34, 247-253. https://doi.org/10.31590/ejosat.1080906

Cited By