In cardiopulmoner operations patients can be perfused with a pulsatile or nonpulsatile pump mode. The extra energy maintained by the pulsatile perfusion may have different effects on the patient and the oxygenator fiber rather than nonpulsatile perfusion. Especially the effect of pulsatile perfusion on the fibers isn’t clearly known. The purpose of this study is to investigate the effects of pulsatile and non-pulsatile blood flows on oxygenator fibers. 18 out of 32 patients that had an pediatric open heart surgery was chosen according to their aortic clamp times. 9 of 18 patients were perfused in a pulsatile mode, other 9 patients were perfused in a nonpulsatile mode. The patient blood was collected before the open heart surgery (T1), before aortic clamp (T2), after aortic clamp (T3), after 1st intensive care hour (T4) and after the 1st intensive care day (T5) in order to compare the results of whole blood and plasma proteins. At the end of the open heart operation 10 cm of oxygenator fiber was removed from the fiber bundle and taken into the phosfate buffer saline (PBS) solution after the patient had a stabile outcome. Whole blood and micro protein measurements were applied in both first fiber solution and sonicated solution. No harmful effect of pulsatile perfusion on blood cells and proteins was observed according to patient results. More blood cell aggregation and total protein adsorption was observed in nonpulsatile mode fibers results. In this study pulsatile perfusion maintained better blood compability over nonpulsatile perfusion and the extra energy in pulsatile perfusion caused better microcirculation.

Keywords

Kaynakça

  1. Andrade JD, Hlady V., (1987) Plasma protein adsorption: the big twelve. Ann N Y Acad Sci.; 516:158-72.
  2. Baier RE, Dutton RC. (1969), Initial events in interactions of blood with a foreign surface, J Biomed Mater Res,3, 191-206
  3. Boldt J, Knothe C, Zickmann B, Bill S, Dapper F, Hempelmann G., (1993) Platelet function in cardiac surgery: influence of temperature and aprotinin. Ann Thorac Surg. Mar, 55 (3), :652-8.
  4. Ciaverella D, Snyder EL. Effects ofcardiopulmonary bypass on platelet function (1990), Dutcher JP ed. Modern transfusion therapy. BocaRaton, FL: CRC Press, 3–23.
  5. Driessen J, Dhaese H, Fransen G, Verrelst P, Rondelez L, Gevaert L,(1995) Pulsatile compared with nonpulsatile perfusion using a centrifugal pump for cardiopulmonary bypass during coronary artery bypass grafting. Effects on systemic haemodynamics, oxygenation and inflamatory response parameters, Perfusion, 10:3-12.
  6. Dündar Akif, Frazier OH, Charles D Fraser JR (1999). Defining Pulsatile Perfusion, Quantification in Terms of Energy Equivalent Pressure, Artificial Organs,23 (8),712-716
  7. Feng Qiu, Sameer Khan, Jonathan Talor, Allan Kunselman, Akif Ündar, (2011), Evaluation of two pediatric polymethyl pentene membrane oxygenators with pulsatile and non-pulsatile perfusion, Perfusion, 26 (3) 229–237.
  8. Hyde JAJ, Achinn J, Timothy RG, (1998). Platelets and Cardiopulmnary Bypass, Perfusion, 13, 389-407

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mühendislik

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

30 Kasım 2021

Gönderilme Tarihi

1 Haziran 2021

Kabul Tarihi

21 Ağustos 2021

Yayımlandığı Sayı

Yıl 2021 Sayı: 27

Kaynak Göster

APA
Gazioğlu, T., Kocakulak, M., Ayhan, F., & Ayhan, H. (2021). Effects of Pulsatile and Non-Pulsatile Perfusion On Oxygenator Fibers During Pediatric Cardiopulmonary Bypass. Avrupa Bilim ve Teknoloji Dergisi, 27, 193-203. https://doi.org/10.31590/ejosat.917027

Cited By