Araştırma Makalesi

Experimental Performance Analysis of a Groundwater Heat Pump System in Erzincan, Turkey

Cilt: 12 Sayı: 3 31 Aralık 2019
PDF İndir
EN TR

Experimental Performance Analysis of a Groundwater Heat Pump System in Erzincan, Turkey

Öz

In this study, a place with a floor area of 80 m² in Erzincan was heated by the Groundwater Heat Pump (GWHP). In this application experimentally investigated, energy and performance analysis of the heat pump and the entire system were performed. Evaporator water flow, condenser water flow and air flows of fan-coil devices was fixed at certain values. Then the measurements have been made under 9 different conditions consisting of these parameters. In the condition which the highest yield is obtained, performance coefficients of the heat pump ( and the system ( were determined 4.27 and 2.92, respectively. In this condition, the average amount of heat discharged from the condenser was calculated to be 14.3 kW. On the other hand, Groundwater quality and temperature that is an important criterion of the GWHP system was found to applicable to Erzincan. 

Anahtar Kelimeler

Kaynakça

  1. Aksu, B. 2010. The Investigation of The Performance of Ground-Water Sourced Heat Pump in Balikesir. Master Thesis, Gazi University, Ankara, Turkey.
  2. Bakirci, K. 2010. Evaluation of The Performance of A Ground-Source Heat-Pump System With Series GHE (Ground Heat Exchanger) in The Cold Climate Region, Energy, 35, 3088–3096.
  3. Chua, K.J., Chou, S.K. and Yang, W.M. 2010. Advances in Heat Pump Systems: A review. Applied Energy, 87, 3611–3624.
  4. Errera, M.R., Lorente, S. and Bejan, A. 2014. Assemblies of Heat Pumps Served by A Single Underground Heat Exchanger. International Journal of Heat and Mass Transfer, 75, 327–336.
  5. Fei, L. and Pingfang, H. 2012. Energy and Exergy Analysis of a Ground Water Heat Pump System. Physics Procedia, 24, 169–175.
  6. Haiwen, S., Lin, D., Xiangli, L. and Yingxin, Z. 2010. Quasi-Dynamic Energy-Saving Judgment of Electric-Driven Seawater Source Heat Pump District Heating System Over Boiler House District Heating System, Energy and Buildings, 42, 2424–2430.
  7. Holman, I.P. 1994. Experimental Methods for Engineers. 6th ed. McGraw- Hill.
  8. Kural, A.K. 2012. Comparison of application of ground source heat pump with central air conditioning and natural gas systems in a building in Malatya. Master Thesis, Inonu University, Malatya, Turkey.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mühendislik

Bölüm

Araştırma Makalesi

Yazarlar

Mehmet Kaya
Türkiye

Yayımlanma Tarihi

31 Aralık 2019

Gönderilme Tarihi

17 Ekim 2018

Kabul Tarihi

9 Ekim 2019

Yayımlandığı Sayı

Yıl 2019 Cilt: 12 Sayı: 3

Kaynak Göster

APA
Kalkan, O., & Kaya, M. (2019). Experimental Performance Analysis of a Groundwater Heat Pump System in Erzincan, Turkey. Erzincan University Journal of Science and Technology, 12(3), 1254-1265. https://doi.org/10.18185/erzifbed.471714
AMA
1.Kalkan O, Kaya M. Experimental Performance Analysis of a Groundwater Heat Pump System in Erzincan, Turkey. Erzincan University Journal of Science and Technology. 2019;12(3):1254-1265. doi:10.18185/erzifbed.471714
Chicago
Kalkan, Orhan, ve Mehmet Kaya. 2019. “Experimental Performance Analysis of a Groundwater Heat Pump System in Erzincan, Turkey”. Erzincan University Journal of Science and Technology 12 (3): 1254-65. https://doi.org/10.18185/erzifbed.471714.
EndNote
Kalkan O, Kaya M (01 Aralık 2019) Experimental Performance Analysis of a Groundwater Heat Pump System in Erzincan, Turkey. Erzincan University Journal of Science and Technology 12 3 1254–1265.
IEEE
[1]O. Kalkan ve M. Kaya, “Experimental Performance Analysis of a Groundwater Heat Pump System in Erzincan, Turkey”, Erzincan University Journal of Science and Technology, c. 12, sy 3, ss. 1254–1265, Ara. 2019, doi: 10.18185/erzifbed.471714.
ISNAD
Kalkan, Orhan - Kaya, Mehmet. “Experimental Performance Analysis of a Groundwater Heat Pump System in Erzincan, Turkey”. Erzincan University Journal of Science and Technology 12/3 (01 Aralık 2019): 1254-1265. https://doi.org/10.18185/erzifbed.471714.
JAMA
1.Kalkan O, Kaya M. Experimental Performance Analysis of a Groundwater Heat Pump System in Erzincan, Turkey. Erzincan University Journal of Science and Technology. 2019;12:1254–1265.
MLA
Kalkan, Orhan, ve Mehmet Kaya. “Experimental Performance Analysis of a Groundwater Heat Pump System in Erzincan, Turkey”. Erzincan University Journal of Science and Technology, c. 12, sy 3, Aralık 2019, ss. 1254-65, doi:10.18185/erzifbed.471714.
Vancouver
1.Orhan Kalkan, Mehmet Kaya. Experimental Performance Analysis of a Groundwater Heat Pump System in Erzincan, Turkey. Erzincan University Journal of Science and Technology. 01 Aralık 2019;12(3):1254-65. doi:10.18185/erzifbed.471714