Derleme

Audibility Assessment of Fire Alarm System Sound Level for Industrial Processes

Cilt: 13 Sayı: 3 30 Eylül 2025
PDF İndir
EN TR

Audibility Assessment of Fire Alarm System Sound Level for Industrial Processes

Öz

Fire alarm systems are the first stage of fire evacuation. The audibility of the fire alarm is of vital importance. In industrial buildings, there is almost continuous occupational noise. Variables such as duration, frequency, level and frequency range of this noise may vary depending on the work performed. In this study, the audibility of the fire alarm when it sounds during the process is evaluated. Audibility is based on the sound level. Sound levels for various processes were obtained from the literature. In our country, the sound levels of audible fire alarm systems are specified in the “Regulation on Fire Protection of Buildings”. According to this, the lowest alarm level is 65 dB(A), and the maximum total is 75 dB(A) with +10 dB(A) in places characterized as “noisy”. The maximum sound level allowed by the regulation is 120 dB(A). The sound level generated in the environment was calculated by calculating the fire alarm sound level and the sound levels of the processes together. The results show that the fire alarm sound level at the lower limit is not sufficient for process noise, while the fire alarm level at the upper limit corresponds to the “pain threshold”.

Anahtar Kelimeler

Kaynakça

  1. [1] Y. Zhu, G. Kong, and C. Che, “Thermally-induced self-cutting surfaced reduced graphene oxide fibers for smart fire alarm,” Colloids Surf A Physicochem Eng Asp, vol. 675, p. 132032, Oct. 2023, doi: 10.1016/j.colsurfa.2023.132032.
  2. [2] M. Yu, H. Yuan, K. Li, and J. Wang, “Research on multi-detector real-time fire alarm technology based on signal similarity,” Fire Saf J, vol. 136, p. 103724, Apr. 2023, doi: 10.1016/j.firesaf.2022.103724.
  3. [3] X. Han, T. Lu, H. Wang, Z. Zhang, and S. Lu, “Phytic acid modified soy protein isolate/chitosan film: A multi-functional and degradable bio-based composite material for fire alarm sensor,” Polym Degrad Stab, vol. 216, p. 110505, Oct. 2023, doi: 10.1016/j.polymdegradstab.2023.110505.
  4. [4] M. F. Pekşen, Y. Kaya, Y. Uyaroğlu, H. S. Soyhan, and C. Çelik, “Kocaeli İli Yangın Karakteristiklerinin İncelenmesi,” Uluslararası Yakıtlar Yanma Ve Yangın Dergisi, vol. 10, no. 1, pp. 9–20, Dec. 2022, doi: 10.52702/fce.1079533.
  5. [5] Ü. Arpacıoğlu, “Yangın Olgusu ve Yüksek Yapılarda Yangın Güvenliği,” Yüksek Lisans Tezi, Mimar Sinan Güzel Sanatlar Üniversitesi, İstanbul, 2004.
  6. [6] M. Yaman and F. Demirel, “Cephelerde Yangın Güvenlik Önlemleri ve Mevzuatların Karşılaştırmalı Analizi,” Uluslararası Doğu Anadolu Fen Mühendislik ve Tasarım Dergisi, vol. 2, no. 1, pp. 88–108, 2020.
  7. [7] T.C. Cumhurbaşkanlığı Yönetmeliği, “Binaların Yangından Korunması Hakkında Yönetmelik.”
  8. [8] H. Başdemir, “Eğitim Yapılarında Pasif Yangın Güvenlik Analizi,” Afet ve Risk Dergisi, vol. 5, no. 1, pp. 151–166, Jun. 2022, doi: 10.35341/afet.1000172.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mimarlık (Diğer), Yangın Güvenliği Tasarımı

Bölüm

Derleme

Yayımlanma Tarihi

30 Eylül 2025

Gönderilme Tarihi

6 Haziran 2025

Kabul Tarihi

29 Temmuz 2025

Yayımlandığı Sayı

Yıl 2025 Cilt: 13 Sayı: 3

Kaynak Göster

APA
Bilmez, D. H., & Özgünler, M. (2025). Audibility Assessment of Fire Alarm System Sound Level for Industrial Processes. Gazi University Journal of Science Part B: Art Humanities Design and Planning, 13(3), 353-368. https://izlik.org/JA54KY23HR
AMA
1.Bilmez DH, Özgünler M. Audibility Assessment of Fire Alarm System Sound Level for Industrial Processes. GUJSPB. 2025;13(3):353-368. https://izlik.org/JA54KY23HR
Chicago
Bilmez, Derin Hilal, ve Mustafa Özgünler. 2025. “Audibility Assessment of Fire Alarm System Sound Level for Industrial Processes”. Gazi University Journal of Science Part B: Art Humanities Design and Planning 13 (3): 353-68. https://izlik.org/JA54KY23HR.
EndNote
Bilmez DH, Özgünler M (01 Eylül 2025) Audibility Assessment of Fire Alarm System Sound Level for Industrial Processes. Gazi University Journal of Science Part B: Art Humanities Design and Planning 13 3 353–368.
IEEE
[1]D. H. Bilmez ve M. Özgünler, “Audibility Assessment of Fire Alarm System Sound Level for Industrial Processes”, GUJSPB, c. 13, sy 3, ss. 353–368, Eyl. 2025, [çevrimiçi]. Erişim adresi: https://izlik.org/JA54KY23HR
ISNAD
Bilmez, Derin Hilal - Özgünler, Mustafa. “Audibility Assessment of Fire Alarm System Sound Level for Industrial Processes”. Gazi University Journal of Science Part B: Art Humanities Design and Planning 13/3 (01 Eylül 2025): 353-368. https://izlik.org/JA54KY23HR.
JAMA
1.Bilmez DH, Özgünler M. Audibility Assessment of Fire Alarm System Sound Level for Industrial Processes. GUJSPB. 2025;13:353–368.
MLA
Bilmez, Derin Hilal, ve Mustafa Özgünler. “Audibility Assessment of Fire Alarm System Sound Level for Industrial Processes”. Gazi University Journal of Science Part B: Art Humanities Design and Planning, c. 13, sy 3, Eylül 2025, ss. 353-68, https://izlik.org/JA54KY23HR.
Vancouver
1.Derin Hilal Bilmez, Mustafa Özgünler. Audibility Assessment of Fire Alarm System Sound Level for Industrial Processes. GUJSPB [Internet]. 01 Eylül 2025;13(3):353-68. Erişim adresi: https://izlik.org/JA54KY23HR