Araştırma Makalesi

Examining the Effect of Venipuncture Technique with Vacutainer and Injector on the Rate of Hemolysis

Cilt: 7 Sayı: 2 31 Mayıs 2022
PDF İndir
TR EN

Examining the Effect of Venipuncture Technique with Vacutainer and Injector on the Rate of Hemolysis

Öz

Objective: This study was conducted to determine hemolysis rates for venous blood samples drawn by injector and vacutainer holder and to assess the effect of the venipuncture technique on the process of hemolysis. Material and Method: This cross-sectional and analytical study was conducted with 128 patients who were admitted to the Cardiology and Angio clinics of a university hospital and met the inclusion criteria. One group of patients who were to have routine biochemical tests underwent venipuncture with an injector, and another group with a vacutainer. Results: The serum hemolysis level is not significantly different by gender. No significant correlation was found between blood serum hemolysis levels and age or Body Mass Index with blood drawn with an injector or with a vacutainer. While the serum hemolysis level was on average 0.11 g/dl in blood drawn with an injector, the level in blood drawn with a vacutainer was 0.06 g/dl; the difference was not statistically significant. Conclusion: This study revealed that there was no statistically significant difference between hemolysis rates in blood drawn with an injector or with a vacutainer. However, the hemolysis rates in blood drawn with an injector were almost twice the rates noted in blood drawn with a vacutainer, and this difference may be clinically significant.

Anahtar Kelimeler

Kaynakça

  1. Cadacio C, Nachamkin I. A novel needle-free blood draw device for sample collection from short peripheral catheters. J Infus Nurs. 2017;40(3):156-162.
  2. Makhumula‐ Nkhoma N, Weston KL, McSherry R., et al. The impact of venepuncture training on the reduction of pre‐ analytical blood sample haemolysis rates: A systematic review. J Clin Nurs. 2019;28(23-24):4166-4176.
  3. Heireman L, Van Geel P, Musger L., et al. Causes, consequences and management of sample hemolysis in the clinical laboratory. Clin Biochem. 2017;50: 1317- 1322.
  4. Marques-Garcia F. Methods for hemolysis interference study in laboratory medicine–a critical review. EJIFCC. 2020;31(1):85-97.
  5. Plebani M. Quality Indicators to Detect Pre-Analytical Errors in Laboratory Testing. Clin Biochem Rev. 2012;33(3):85-88.
  6. Aksit MZ, Yalcın H, Bilgi PT., et al. [Evaluation of causes of preanalytical rejections in our emergency laboratory]. The Journal of Tepecik Education and Research Hospital. 2016;26(1):41-45.
  7. Chawla R, Goswami B, Singh B., et al. Evaluating laboratory performance with quality indicators. Laboratory Medicine. 2010;41(5):297-300.
  8. Lippi G, Avanzini P, Cervellin G. Prevention of hemolysis in blood samples collected from intravenous catheters. Clin Biochem. 2013;46(7-8):561-4.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Sağlık Kurumları Yönetimi

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

31 Mayıs 2022

Gönderilme Tarihi

13 Temmuz 2021

Kabul Tarihi

20 Mayıs 2022

Yayımlandığı Sayı

Yıl 2022 Cilt: 7 Sayı: 2

Kaynak Göster

APA
Ceylan, B., Aksun, S., Akbıyık, A., Uzelli Yılmaz, D., & Akın Korhan, E. (2022). Examining the Effect of Venipuncture Technique with Vacutainer and Injector on the Rate of Hemolysis. İzmir Katip Çelebi Üniversitesi Sağlık Bilimleri Fakültesi Dergisi, 7(2), 307-312. https://izlik.org/JA78ZN45HD
AMA
1.Ceylan B, Aksun S, Akbıyık A, Uzelli Yılmaz D, Akın Korhan E. Examining the Effect of Venipuncture Technique with Vacutainer and Injector on the Rate of Hemolysis. İKÇÜSBFD. 2022;7(2):307-312. https://izlik.org/JA78ZN45HD
Chicago
Ceylan, Burcu, Saliha Aksun, Ayşe Akbıyık, Derya Uzelli Yılmaz, ve Esra Akın Korhan. 2022. “Examining the Effect of Venipuncture Technique with Vacutainer and Injector on the Rate of Hemolysis”. İzmir Katip Çelebi Üniversitesi Sağlık Bilimleri Fakültesi Dergisi 7 (2): 307-12. https://izlik.org/JA78ZN45HD.
EndNote
Ceylan B, Aksun S, Akbıyık A, Uzelli Yılmaz D, Akın Korhan E (01 Mayıs 2022) Examining the Effect of Venipuncture Technique with Vacutainer and Injector on the Rate of Hemolysis. İzmir Katip Çelebi Üniversitesi Sağlık Bilimleri Fakültesi Dergisi 7 2 307–312.
IEEE
[1]B. Ceylan, S. Aksun, A. Akbıyık, D. Uzelli Yılmaz, ve E. Akın Korhan, “Examining the Effect of Venipuncture Technique with Vacutainer and Injector on the Rate of Hemolysis”, İKÇÜSBFD, c. 7, sy 2, ss. 307–312, May. 2022, [çevrimiçi]. Erişim adresi: https://izlik.org/JA78ZN45HD
ISNAD
Ceylan, Burcu - Aksun, Saliha - Akbıyık, Ayşe - Uzelli Yılmaz, Derya - Akın Korhan, Esra. “Examining the Effect of Venipuncture Technique with Vacutainer and Injector on the Rate of Hemolysis”. İzmir Katip Çelebi Üniversitesi Sağlık Bilimleri Fakültesi Dergisi 7/2 (01 Mayıs 2022): 307-312. https://izlik.org/JA78ZN45HD.
JAMA
1.Ceylan B, Aksun S, Akbıyık A, Uzelli Yılmaz D, Akın Korhan E. Examining the Effect of Venipuncture Technique with Vacutainer and Injector on the Rate of Hemolysis. İKÇÜSBFD. 2022;7:307–312.
MLA
Ceylan, Burcu, vd. “Examining the Effect of Venipuncture Technique with Vacutainer and Injector on the Rate of Hemolysis”. İzmir Katip Çelebi Üniversitesi Sağlık Bilimleri Fakültesi Dergisi, c. 7, sy 2, Mayıs 2022, ss. 307-12, https://izlik.org/JA78ZN45HD.
Vancouver
1.Burcu Ceylan, Saliha Aksun, Ayşe Akbıyık, Derya Uzelli Yılmaz, Esra Akın Korhan. Examining the Effect of Venipuncture Technique with Vacutainer and Injector on the Rate of Hemolysis. İKÇÜSBFD [Internet]. 01 Mayıs 2022;7(2):307-12. Erişim adresi: https://izlik.org/JA78ZN45HD