Araştırma Makalesi

AUTOMATIC BELT CARDIOPULMONARY RECISUTATION (CPR) DEVICE AND TEST SYSTEM DESIGN

Cilt: 11 Sayı: 2 28 Haziran 2023
PDF İndir
TR EN

AUTOMATIC BELT CARDIOPULMONARY RECISUTATION (CPR) DEVICE AND TEST SYSTEM DESIGN

Öz

The test system was created by adding flex and force sensors to this manikin to evaluate the results of heart massage applied on an artificial adult manikin, which has a spring that can give the chest stiffness of an adult human. This test system monitors and analyzes cardiopulmonary resuscitation (CPR) applications performed by the automated CPR device or manually by the person. The signals received from the sensor are transferred to the computer via the serial port with the Arduino Uno card and displayed in real-time in MATLAB graphical user interface (GUI). This GUI, designed with Matlab 2021a software, analyzes the sensor signals resulting from CPR. It gives a graph of the repeats of compression per minute, the depth of each compression, and the compressions rate variable performed by the user or the automatic CPR device during the CPR application. This created test system can evaluate the accuracy of both the automatic CPR device performed in this study and the manual CPR application. The test system designed in this respect can be used in the training and evaluation of cardiac massage applications, which is included in the first aid courses in secondary education, associate degree, undergraduate, and vocational education courses.

Anahtar Kelimeler

Destekleyen Kurum

Karabük Üniversitesi

Proje Numarası

FYL-2020-2265

Teşekkür

By Karabuk University Scientific Research Projects Coordination Unit thank you for the support given to this work with project number FYL-2020-2265.

Kaynakça

  1. Araç, S. , Zengin, Y. , İçer, M. , Gündüz, E. , Dursun, R. , Durgun, H. , Üstündağ, M. , Orak, M. , Kuyumcu, M. & Güloğlu, C., 2021. Acil Serviste Kardiyopulmoner Resüsitasyon Yapılan Hastaların Değerlendirilmesi; Retrospektif Çalışma. Abant Tıp Dergisi, 10 (1), 140–151.
  2. Berkom, P., Noordergraaf, G., Scheffer, G., Noordergraaf, A., 2008. Does use of the CPREzyTM involve more work than CPR without feedback?. Resuscitation, 78, 66–70.
  3. Carl, B., & Brook, S., 1985. United States patent. Geothermics, 14(4), 595–599.
  4. Çolak, İ. ve Bayındır R., 2005. PIC16F877 ile DA Motor Hız Kontrolü, Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, 11 (2), 277–285.
  5. Ikeno, F., 2003. Improved survival with a novel chest compression device during a porcine model of cardiac arrest. Circulation, 108 (17), 381–383.
  6. Ikram, U. H., Jai, P. U., Sharda, U., Douglas, W. T., Jonathan J. S., ve Arno, L. Z., 2008. Chest compression quality and rescuer fatigue with increased compression to ventilation ratio during single rescuer pediatric CPR. Resuscitation, 79, 82–89.
  7. İnal, M., Yıldız, U., Öğütçü, S., Pekdemir, M., Ünlüer, T., Çelikhası, C., Ayüz, E., Işık, E., 2021. Tıp Eğitiminde CPR Mankenlerinin Yapay Zeka Sınıflandırıcı ile Dijital Dönüşümü. Veri Bilimi Dergisi, 4(3), 81–88.
  8. Majer, J., Jaguszewski, M.J., Frass, M., Leskiewicz, M., Smereka, J., Ladny, J.R., Robak, O., Szarpak, L., 2019. Does the use of cardiopulmonary resuscitation feedback devices improve the quality of chest compressions performed by doctors? A prospective, randomized, cross-over simulation study. Cardiology Journal, 26, 5, 529–535.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mühendislik

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

28 Haziran 2023

Gönderilme Tarihi

31 Ağustos 2022

Kabul Tarihi

22 Aralık 2022

Yayımlandığı Sayı

Yıl 2023 Cilt: 11 Sayı: 2

Kaynak Göster

APA
Kavsaoğlu, A. R., & Tamokur, M. A. (2023). AUTOMATIC BELT CARDIOPULMONARY RECISUTATION (CPR) DEVICE AND TEST SYSTEM DESIGN. Mühendislik Bilimleri ve Tasarım Dergisi, 11(2), 474-485. https://doi.org/10.21923/jesd.1168807
AMA
1.Kavsaoğlu AR, Tamokur MA. AUTOMATIC BELT CARDIOPULMONARY RECISUTATION (CPR) DEVICE AND TEST SYSTEM DESIGN. MBTD. 2023;11(2):474-485. doi:10.21923/jesd.1168807
Chicago
Kavsaoğlu, Ahmet Reşit, ve Mehmet Ali Tamokur. 2023. “AUTOMATIC BELT CARDIOPULMONARY RECISUTATION (CPR) DEVICE AND TEST SYSTEM DESIGN”. Mühendislik Bilimleri ve Tasarım Dergisi 11 (2): 474-85. https://doi.org/10.21923/jesd.1168807.
EndNote
Kavsaoğlu AR, Tamokur MA (01 Haziran 2023) AUTOMATIC BELT CARDIOPULMONARY RECISUTATION (CPR) DEVICE AND TEST SYSTEM DESIGN. Mühendislik Bilimleri ve Tasarım Dergisi 11 2 474–485.
IEEE
[1]A. R. Kavsaoğlu ve M. A. Tamokur, “AUTOMATIC BELT CARDIOPULMONARY RECISUTATION (CPR) DEVICE AND TEST SYSTEM DESIGN”, MBTD, c. 11, sy 2, ss. 474–485, Haz. 2023, doi: 10.21923/jesd.1168807.
ISNAD
Kavsaoğlu, Ahmet Reşit - Tamokur, Mehmet Ali. “AUTOMATIC BELT CARDIOPULMONARY RECISUTATION (CPR) DEVICE AND TEST SYSTEM DESIGN”. Mühendislik Bilimleri ve Tasarım Dergisi 11/2 (01 Haziran 2023): 474-485. https://doi.org/10.21923/jesd.1168807.
JAMA
1.Kavsaoğlu AR, Tamokur MA. AUTOMATIC BELT CARDIOPULMONARY RECISUTATION (CPR) DEVICE AND TEST SYSTEM DESIGN. MBTD. 2023;11:474–485.
MLA
Kavsaoğlu, Ahmet Reşit, ve Mehmet Ali Tamokur. “AUTOMATIC BELT CARDIOPULMONARY RECISUTATION (CPR) DEVICE AND TEST SYSTEM DESIGN”. Mühendislik Bilimleri ve Tasarım Dergisi, c. 11, sy 2, Haziran 2023, ss. 474-85, doi:10.21923/jesd.1168807.
Vancouver
1.Ahmet Reşit Kavsaoğlu, Mehmet Ali Tamokur. AUTOMATIC BELT CARDIOPULMONARY RECISUTATION (CPR) DEVICE AND TEST SYSTEM DESIGN. MBTD. 01 Haziran 2023;11(2):474-85. doi:10.21923/jesd.1168807