Araştırma Makalesi

SAMPLE ENTROPY ANALYSIS OF HEART RATE VARIABILITY IN RR INTERVAL DETECTION

Cilt: 8 Sayı: 3 24 Eylül 2020
PDF İndir
EN TR

SAMPLE ENTROPY ANALYSIS OF HEART RATE VARIABILITY IN RR INTERVAL DETECTION

Öz

Entropy is a robust method that is able to measure irregularities or the general behavior of the complex time series which could be continuously interact with many different and independent factors in time. This study aimed to investigate the sample entropy measurement of heart rate variability (HRV) for evaluating of 50Hz interference and baseline wander (BW) noise effects on RR interval. Three different synthetic electrocardiogram (ECG) signals were recorded using the simulator device. Sample Entropy (SampEn) values of full length and windowed length of data were calculated to track and identify RR intervals. It was found that adult normal sinus rhythm (NSR) signal without noise had the most regular and consistent results while adult ECG signal with BW noisy had the most irregular and inconsistent results. Furthermore, the BW noisy had more effect on irregularity ECG signal than 50 Hz interference. Consequently, the SampEn provided the measurement of irregularity and randomness of ECG data. However, it was found that the determination of RR intervals for classification and decision support systems was not practical in real-time analysis of HRV from raw ECG recordings because of noisy affect.

Anahtar Kelimeler

Kaynakça

  1. Alcan V., Uçar M., 2019. Investigation of The Sensitivity Tolerance Parameter to Noise-Related Effect Using Sample Entropy. CISET - 2nd Cilicia International Symposium on Engineering and Technology; 146-149
  2. Baig M.M., Gholamhosseini H., Connolly M.J., 2013. A comprehensive survey of wearable and wireless ECG monitoring systems for older adults, Medical & Biological Engineering & Computing, 51, 485-495.
  3. Ferrario M., Signorini M.G., Magenes G., Cerutti S., 2006. Comparison of entropy-based regularity estimators: application to the fetal heart rate signal for the identification of fetal distress, IEEE Transactions on Biomedical Engineering, 53,119-125.
  4. Guo H.W., Huang Y.S., Chien J.C., Shieh J.S., 2015. Short-term analysis of heart rate variability for emotion recognition via a wearable ECG device, IEEE International Conference on Intelligent Informatics and Biomedical Sciences 262-265.
  5. Kaya H., Uçar E., Alcan V.,2019. A Multiscale Entropy Based Approach For Analysis Of Surface EMG Signals. 2nd Cilicia International Symposium on Engineering and Technology,306-310
  6. Kleiger R.E., Stein P.K., Bigger J.T., 2005. Jr. Heart rate variability: measurement and clinical utility, Annual Noninvasive Electrocardiology, 10,88-101.
  7. Kuntzelman K., Jack Rhodes L., Harrington L. N., Miskovic V., 2018. A practical comparison of algorithms for the measurement of multiscale entropy in neural time series data, Brain and Cognition, 123, 126-135.
  8. Lake D.E., Richman J.S., Griffin M.P., Moorman J.R., 2002. Sample entropy analysis of neonatal heart rate variability, American Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 283, 789-797.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Bilgisayar Yazılımı

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

24 Eylül 2020

Gönderilme Tarihi

29 Mayıs 2020

Kabul Tarihi

7 Temmuz 2020

Yayımlandığı Sayı

Yıl 2020 Cilt: 8 Sayı: 3

Kaynak Göster

APA
Alcan, V. (2020). SAMPLE ENTROPY ANALYSIS OF HEART RATE VARIABILITY IN RR INTERVAL DETECTION. Mühendislik Bilimleri ve Tasarım Dergisi, 8(3), 783-790. https://doi.org/10.21923/jesd.745275
AMA
1.Alcan V. SAMPLE ENTROPY ANALYSIS OF HEART RATE VARIABILITY IN RR INTERVAL DETECTION. MBTD. 2020;8(3):783-790. doi:10.21923/jesd.745275
Chicago
Alcan, Veysel. 2020. “SAMPLE ENTROPY ANALYSIS OF HEART RATE VARIABILITY IN RR INTERVAL DETECTION”. Mühendislik Bilimleri ve Tasarım Dergisi 8 (3): 783-90. https://doi.org/10.21923/jesd.745275.
EndNote
Alcan V (01 Eylül 2020) SAMPLE ENTROPY ANALYSIS OF HEART RATE VARIABILITY IN RR INTERVAL DETECTION. Mühendislik Bilimleri ve Tasarım Dergisi 8 3 783–790.
IEEE
[1]V. Alcan, “SAMPLE ENTROPY ANALYSIS OF HEART RATE VARIABILITY IN RR INTERVAL DETECTION”, MBTD, c. 8, sy 3, ss. 783–790, Eyl. 2020, doi: 10.21923/jesd.745275.
ISNAD
Alcan, Veysel. “SAMPLE ENTROPY ANALYSIS OF HEART RATE VARIABILITY IN RR INTERVAL DETECTION”. Mühendislik Bilimleri ve Tasarım Dergisi 8/3 (01 Eylül 2020): 783-790. https://doi.org/10.21923/jesd.745275.
JAMA
1.Alcan V. SAMPLE ENTROPY ANALYSIS OF HEART RATE VARIABILITY IN RR INTERVAL DETECTION. MBTD. 2020;8:783–790.
MLA
Alcan, Veysel. “SAMPLE ENTROPY ANALYSIS OF HEART RATE VARIABILITY IN RR INTERVAL DETECTION”. Mühendislik Bilimleri ve Tasarım Dergisi, c. 8, sy 3, Eylül 2020, ss. 783-90, doi:10.21923/jesd.745275.
Vancouver
1.Veysel Alcan. SAMPLE ENTROPY ANALYSIS OF HEART RATE VARIABILITY IN RR INTERVAL DETECTION. MBTD. 01 Eylül 2020;8(3):783-90. doi:10.21923/jesd.745275

Cited By