BibTex RIS Kaynak Göster

Measurements of Electric and Magnetic Field Intensities at 50 Hz Mains Frequency and Comparison of Measurement Results to ICNIRP's Reference Levels for General Public Exposure

Yıl 2014, Cilt: 20 Sayı: 8, 294 - 299, 01.08.2014

Öz

International Commission on Non-Ionizing Radiation Protection (ICNIRP) accepted by many countries as well as Turkey is a commission which determines reference levels for general public and occupational exposure to electromagnetic fields and has intensive works on these issues. ICNIRP has published separately a low frequency band (0-100 kHz) and a high frequency band (100 kHz-300 GHz) guidelines which investigate the biological and potential health hazard effects of electric, magnetic and electromagnetic fields. In this study, measurements of low frequency electric and magnetic fields were taken in 30 different locations in the city center of Diyarbakir. Some locations exceeding the reference levels for general public exposure specified by ICNIRP were determined in the measurements of low frequency electric and magnetic fields and then some assessments were made about them. Low frequency electric and magnetic field meter device which is named EHP-50C was used in the measurements. The measurement results were calculated as an average value of 6 minute measurements. In addition, under a high voltage power line during 60 minutes, electric and magnetic field intensity values were recorded in the same manner. As a result of recordings, changes in the electric and magnetic field intensity values were observed, and then these changes were shown on the charts.

Kaynakça

  • Paolino L, Sebillo M, Tortora G, Vitiello G. “Monitoring Electromagnetic Pollution: A Gis-Based Visual Approach”. Lecture Notes in Computer Science, 2184, 90-101, 2001.
  • Bertocco M, Farias M, Offelli C, Sona A. “A Measurement System for Electromagnetic Field”. Proceedings of the 19th IEEE Instrumentation and Measurement Technology Conference, Anchorage, USA, 21-23 May 2002. of Environmental
  • Bornkessel C, Schubert M, Wuschek M, Schmidt P. “Measurement and Calculation of General Public Electromagnetic Exposure Around GSM and UMTS Cellular Base Stations". International ITG-Conference on Antennas, Munich, Germany, 28-30 May 2007.
  • Radovic D, simic M. “System for Automatic Measurement of Signal Level in GSM 900/1800 Channel with GPS Localization”. 10th Telecommunication Forum Telfor, Belgrade, Serbia, 26-28 November 2002.
  • Henderson SI, Bangay MJ. “Survey of RF Exposure Levels from Mobile Telephone Base Stations in Australia”. Bioelectromagnetics, 27(1), 73-76, 2005.
  • Önal E. Elektromanyetik Alanlarin Canlı Organizmalara Etkilerinin İncelenmesi. Yüksek Lisans Tezi, İnönü Üniversitesi, Malatya, Türkiye, 2005.
  • Elhasoğlu D. Elektromanyetik Kirliliğin Zararlı Etkileri. Yüksek Lisans Tezi, Çukurova Üniversitesi, Adana, Türkiye, 2006.
  • Tekintanğaç Y. Cep Telefonları Tarafından Oluşturulan Elektromanyetik Alanın Kobay EKG’si Üzerine Etkisi. Yüksek Lisans Tezi, Yüzüncü Yıl Üniversitesi, Van, Türkiye, 2006.
  • İnce T. Elektromanyetik Kirlilik. Yüksek Lisans Tezi, Gazi Üniversitesi, Ankara, Türkiye, 2011.
  • Çerezci O, Kartal Z, Pala K, Türkkan A. “Elektromanyetik Alan ve Sağlık Etkileri”. Nilüfer Belediyesi, Bursa Türkiye, 2012.
  • İlhan MN. Bir Tıp Fakültesi Hastanesinde Elektromanyetik Alan Haritası Çıkarılması ve Sağlık Çalışanlarında Sağlık Etkilerinin Belirlenmesi. Yüksek Lisans Tezi, Ankara Üniversitesi, Ankara, Türkiye, 2008.
  • Uygunol O, Durduran SS. “Coğrafi Bilgi Sistemi Yardımıyla GSM Baz İstasyonlarında Elektromanyetik Alan Kirlilik Tespiti ve Konya Örneği”. TMMOB Harita ve Kadastro Mühendisleri Odası Türkiye Harita Bilimsel ve Teknik Kurultayı, Ankara, Türkiye, 11-15 Mayıs 2009.
  • Bilgi Teknolojileri ve İletişim Kurumu. “RF Dielektrik Kaynak Makinası Ortamında EM Işınım (Hasan DİNÇER)”. http://www.tk.gov.tr/tuketici/emd/RFkaynak.pdf (12.04.2014).
  • Genç Ö. Radyo Frekanslarında Elektromanyetik Kirliliğe GSM Bantlarının Etkisinin İstatistiksel Analizi. Doktora Tezi, Selçuk Üniversitesi, Konya, Türkiye, 2010.
  • Cansız M, Kurt MB, “Drive Test Yöntemi ile Elektromanyetik Kirlilik Haritasının Çıkartılması ve Ölçüm Sonuçlarının Mühendislik Fakültesi Mühendislik Dergisi, 3(2), 101-110, 2012. Dicle Üniversitesi
  • International Commission on Non-Ionizing Radiation Protection. “Exposure to Static and Low Frequency Electromagnetic Fields, Biological Effects and Health Consequences (0 Hz-100 kHz)”. International Commission on Non-ionizing Radiation Protection, Munich, Germany, 13, 2003.
  • International Commission on Non-Ionizing Radiation Protection. “Exposure to static and low frequency electromagnetic fields, biological effects and health consequences (100 kHz-300 GHz)”. International Commission on Non-ionizing Radiation Protection, Oberschleißheim, Germany, 16, 2009.
  • Narda Product Group. "Narda Product Group Web Page - Home". https://www.narda-sts.com (05.04.2014).
  • Garmin. “Garmin - United States Web Page - Home”. http://www.garmin.com (05.04.2014).

50 Hz Şebeke Frekansında Elektrik ve Manyetik Alan Şiddetlerinin Ölçülmesi Ve Ölçüm Sonuçlarının ICNIRP'nin Halk Maruziyeti Limitlerine Göre Karşılaştırılması

Yıl 2014, Cilt: 20 Sayı: 8, 294 - 299, 01.08.2014

Öz

Türkiye'nin de içinde bulunduğu birçok ülke tarafından kabul gören Uluslararası İyonlaştırmayan Radyasyondan Korunma Komisyonu (ICNIRP), elektromanyetik alanlara halk ve mesleki maruziyet limitlerini belirleyen ve bu konularda yoğun çalışmalar yapan uluslararası bir komisyondur. ICNIRP elektrik, manyetik ve elektromanyetik alanların biyolojik ve potansiyel sağlık etkilerini incelemek üzere frekans bandını düşük frekans (0-100 Khz) ve yüksek frekans (100 Khz-300 Ghz) bandı olmak üzere ayrı ayrı incelemiş ve farklı kılavuzlar şeklinde yayınlamıştır. Bu çalışmada, düşük frekanslı elektrik ve manyetik alan ölçümleri Diyarbakır İl Merkezi'nin 30 farklı noktasında gerçekleştirilmiştir. Düşük frekans kaynaklı elektrik ve manyetik alan ölçümlerinde ICNIRP'nin belirlemiş olduğu halk maruziyeti limit değerlerini aşan yerlerin olduğu tespit edilmiş ve bununla ilgili durum değerlendirmesi yapılmıştır. Ölçümlerde EHP-50C isimli düşük frekanslı elektrik ve manyetik alan ölçer cihazı kullanılmıştır. Ölçüm sonuçları 6 dakikalık ölçümlerin ortalama değeri alınarak hesaplanmıştır. Ayrıca bir yüksek gerilim hattının altında 60 dakika boyunca elektrik alan şiddeti değerleri ve aynı şekilde manyetik alan şiddeti değerleri kaydedilmiştir. Kayıtlar sonucunda elektrik ve manyetik alan şiddeti değerlerindeki değişimler gözlemlenmiş ve bu değişimler grafik üzerinde gösterilmiştir.

Kaynakça

  • Paolino L, Sebillo M, Tortora G, Vitiello G. “Monitoring Electromagnetic Pollution: A Gis-Based Visual Approach”. Lecture Notes in Computer Science, 2184, 90-101, 2001.
  • Bertocco M, Farias M, Offelli C, Sona A. “A Measurement System for Electromagnetic Field”. Proceedings of the 19th IEEE Instrumentation and Measurement Technology Conference, Anchorage, USA, 21-23 May 2002. of Environmental
  • Bornkessel C, Schubert M, Wuschek M, Schmidt P. “Measurement and Calculation of General Public Electromagnetic Exposure Around GSM and UMTS Cellular Base Stations". International ITG-Conference on Antennas, Munich, Germany, 28-30 May 2007.
  • Radovic D, simic M. “System for Automatic Measurement of Signal Level in GSM 900/1800 Channel with GPS Localization”. 10th Telecommunication Forum Telfor, Belgrade, Serbia, 26-28 November 2002.
  • Henderson SI, Bangay MJ. “Survey of RF Exposure Levels from Mobile Telephone Base Stations in Australia”. Bioelectromagnetics, 27(1), 73-76, 2005.
  • Önal E. Elektromanyetik Alanlarin Canlı Organizmalara Etkilerinin İncelenmesi. Yüksek Lisans Tezi, İnönü Üniversitesi, Malatya, Türkiye, 2005.
  • Elhasoğlu D. Elektromanyetik Kirliliğin Zararlı Etkileri. Yüksek Lisans Tezi, Çukurova Üniversitesi, Adana, Türkiye, 2006.
  • Tekintanğaç Y. Cep Telefonları Tarafından Oluşturulan Elektromanyetik Alanın Kobay EKG’si Üzerine Etkisi. Yüksek Lisans Tezi, Yüzüncü Yıl Üniversitesi, Van, Türkiye, 2006.
  • İnce T. Elektromanyetik Kirlilik. Yüksek Lisans Tezi, Gazi Üniversitesi, Ankara, Türkiye, 2011.
  • Çerezci O, Kartal Z, Pala K, Türkkan A. “Elektromanyetik Alan ve Sağlık Etkileri”. Nilüfer Belediyesi, Bursa Türkiye, 2012.
  • İlhan MN. Bir Tıp Fakültesi Hastanesinde Elektromanyetik Alan Haritası Çıkarılması ve Sağlık Çalışanlarında Sağlık Etkilerinin Belirlenmesi. Yüksek Lisans Tezi, Ankara Üniversitesi, Ankara, Türkiye, 2008.
  • Uygunol O, Durduran SS. “Coğrafi Bilgi Sistemi Yardımıyla GSM Baz İstasyonlarında Elektromanyetik Alan Kirlilik Tespiti ve Konya Örneği”. TMMOB Harita ve Kadastro Mühendisleri Odası Türkiye Harita Bilimsel ve Teknik Kurultayı, Ankara, Türkiye, 11-15 Mayıs 2009.
  • Bilgi Teknolojileri ve İletişim Kurumu. “RF Dielektrik Kaynak Makinası Ortamında EM Işınım (Hasan DİNÇER)”. http://www.tk.gov.tr/tuketici/emd/RFkaynak.pdf (12.04.2014).
  • Genç Ö. Radyo Frekanslarında Elektromanyetik Kirliliğe GSM Bantlarının Etkisinin İstatistiksel Analizi. Doktora Tezi, Selçuk Üniversitesi, Konya, Türkiye, 2010.
  • Cansız M, Kurt MB, “Drive Test Yöntemi ile Elektromanyetik Kirlilik Haritasının Çıkartılması ve Ölçüm Sonuçlarının Mühendislik Fakültesi Mühendislik Dergisi, 3(2), 101-110, 2012. Dicle Üniversitesi
  • International Commission on Non-Ionizing Radiation Protection. “Exposure to Static and Low Frequency Electromagnetic Fields, Biological Effects and Health Consequences (0 Hz-100 kHz)”. International Commission on Non-ionizing Radiation Protection, Munich, Germany, 13, 2003.
  • International Commission on Non-Ionizing Radiation Protection. “Exposure to static and low frequency electromagnetic fields, biological effects and health consequences (100 kHz-300 GHz)”. International Commission on Non-ionizing Radiation Protection, Oberschleißheim, Germany, 16, 2009.
  • Narda Product Group. "Narda Product Group Web Page - Home". https://www.narda-sts.com (05.04.2014).
  • Garmin. “Garmin - United States Web Page - Home”. http://www.garmin.com (05.04.2014).
Toplam 19 adet kaynakça vardır.

Ayrıntılar

Birincil Dil Türkçe
Bölüm Makale
Yazarlar

Mustafa Cansız Bu kişi benim

Muhammed Bahattin Kurt Bu kişi benim

Ali Recai Çelik Bu kişi benim

Yayımlanma Tarihi 1 Ağustos 2014
Yayımlandığı Sayı Yıl 2014 Cilt: 20 Sayı: 8

Kaynak Göster

APA Cansız, M. ., Kurt, M. B. ., & Çelik, A. R. . (2014). 50 Hz Şebeke Frekansında Elektrik ve Manyetik Alan Şiddetlerinin Ölçülmesi Ve Ölçüm Sonuçlarının ICNIRP’nin Halk Maruziyeti Limitlerine Göre Karşılaştırılması. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, 20(8), 294-299. https://doi.org/10.5505/pajes.2014.47550
AMA Cansız M, Kurt MB, Çelik AR. 50 Hz Şebeke Frekansında Elektrik ve Manyetik Alan Şiddetlerinin Ölçülmesi Ve Ölçüm Sonuçlarının ICNIRP’nin Halk Maruziyeti Limitlerine Göre Karşılaştırılması. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi. Ağustos 2014;20(8):294-299. doi:10.5505/pajes.2014.47550
Chicago Cansız, Mustafa, Muhammed Bahattin Kurt, ve Ali Recai Çelik. “50 Hz Şebeke Frekansında Elektrik Ve Manyetik Alan Şiddetlerinin Ölçülmesi Ve Ölçüm Sonuçlarının ICNIRP’nin Halk Maruziyeti Limitlerine Göre Karşılaştırılması”. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi 20, sy. 8 (Ağustos 2014): 294-99. https://doi.org/10.5505/pajes.2014.47550.
EndNote Cansız M, Kurt MB, Çelik AR (01 Ağustos 2014) 50 Hz Şebeke Frekansında Elektrik ve Manyetik Alan Şiddetlerinin Ölçülmesi Ve Ölçüm Sonuçlarının ICNIRP’nin Halk Maruziyeti Limitlerine Göre Karşılaştırılması. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi 20 8 294–299.
IEEE M. . Cansız, M. B. . Kurt, ve A. R. . Çelik, “50 Hz Şebeke Frekansında Elektrik ve Manyetik Alan Şiddetlerinin Ölçülmesi Ve Ölçüm Sonuçlarının ICNIRP’nin Halk Maruziyeti Limitlerine Göre Karşılaştırılması”, Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, c. 20, sy. 8, ss. 294–299, 2014, doi: 10.5505/pajes.2014.47550.
ISNAD Cansız, Mustafa vd. “50 Hz Şebeke Frekansında Elektrik Ve Manyetik Alan Şiddetlerinin Ölçülmesi Ve Ölçüm Sonuçlarının ICNIRP’nin Halk Maruziyeti Limitlerine Göre Karşılaştırılması”. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi 20/8 (Ağustos 2014), 294-299. https://doi.org/10.5505/pajes.2014.47550.
JAMA Cansız M, Kurt MB, Çelik AR. 50 Hz Şebeke Frekansında Elektrik ve Manyetik Alan Şiddetlerinin Ölçülmesi Ve Ölçüm Sonuçlarının ICNIRP’nin Halk Maruziyeti Limitlerine Göre Karşılaştırılması. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi. 2014;20:294–299.
MLA Cansız, Mustafa vd. “50 Hz Şebeke Frekansında Elektrik Ve Manyetik Alan Şiddetlerinin Ölçülmesi Ve Ölçüm Sonuçlarının ICNIRP’nin Halk Maruziyeti Limitlerine Göre Karşılaştırılması”. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, c. 20, sy. 8, 2014, ss. 294-9, doi:10.5505/pajes.2014.47550.
Vancouver Cansız M, Kurt MB, Çelik AR. 50 Hz Şebeke Frekansında Elektrik ve Manyetik Alan Şiddetlerinin Ölçülmesi Ve Ölçüm Sonuçlarının ICNIRP’nin Halk Maruziyeti Limitlerine Göre Karşılaştırılması. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi. 2014;20(8):294-9.





Creative Commons Lisansı
Bu dergi Creative Commons Al 4.0 Uluslararası Lisansı ile lisanslanmıştır.