A Numerical Study on Determination of the Optimal Hole Diameter and Pitch Value for the Unglazed Transpired Solar Collectors
Öz
This investigation is concerned with the unglazed
transpired solar collector (solar wall) type. With this purpose, the optimum
hole arrangement has been determined by investigating the effect of hole diameter
and pitch on the thermal efficiency of the system for different environmental
condition. A thermodynamic model is used to simulate the heating process within
the system. As a result, for extremely small hole diameters or extremely large
hole pitches, the system works as a Trombe wall (glazed thermal storage wall)
rather than an unglazed transpired solar collector because of the fact that
there is not enough air flow through the absorber.
Anahtar Kelimeler
Kaynakça
- 1] www.solarwall.com.
- [2] Kutscher C.F., “An investigation of heat transfer for air flow through low porosity perforated plates”, Ph.D. Thesis, University of Colorado, Department of Mechanical Engineering, Colorado, USA, (1992).
- [3] Hollick J.C. “Unglazed solar wall air heaters”, Renewable Energy, 5, 415-421, (1994).
- [4] Hollick J.C. “Solar cogeneration panels”, Renewable Energy, 15, 195-200, (1998).
- [5] Shukla A., Nkwetta D.N., Cho Y.J., Stevenson V. and Jones P., “A state of art review on the performance of transpired solar collector”, Renewable and Sustainable Energy Reviews, 16, 3975-3985, (2012).
- [6] Kutscher C.F. “Heat exchange effectiveness and pressure drop for air flow through perforated plates with and without crosswind”, Journal of Heat Transfer, 116, 391-399, (1994).
- [7] Augustus Leon M. and Kumar S., “Mathematical modeling and thermal performance analysis of unglazed transpired solar collectors”, Solar Energy, 81, 62-75, (2007).
- [8] Summers D.N. “Thermal Simulation and Economic Assessment of Unglazed Transpired Collector Systems”, M.Sc. Thesis, University of Wisconsin-Madison, USA, (1995).
Ayrıntılar
Birincil Dil
İngilizce
Konular
Mühendislik
Bölüm
Araştırma Makalesi
Yayımlanma Tarihi
1 Mart 2019
Gönderilme Tarihi
14 Kasım 2017
Kabul Tarihi
-
Yayımlandığı Sayı
Yıl 2019 Cilt: 22 Sayı: 1
Cited By
Investigating environmental effects of different combi boilers using LPG
El-Cezeri Fen ve Mühendislik Dergisi
https://doi.org/10.31202/ecjse.577861