In this study, the microstructure and corrosion properties of Vermicular Graphite Cast Iron (VGCI) produced via different methods and parameters were investigated. VGCI was produced from a base ductile iron material using different proportions of vermiculariser and inoculant. Copper was added to a group of samples as an alloying element. The microstructures and corrosion properties of samples were investigated in saltwater media. The effects of production parameters on the microstructure and corrosion behavior were determined. It was observed that as the ratio of vermiculariser applied was increased, the vermicular graphite ratio and vermicularity was also increased. The matrix grain size decreased while the inoculant and pearlite phase ratio increased due to the addition of copper. In electrochemical corrosion studies, VGCI was superior in corrosion resistance compared to SGCI and addition of vermiculariser, inoculants and copper was found effective in improving the corrosion resistance of the VGCI material.

Anahtar Kelimeler

Kaynakça

  1. [1] Akinribide O J, Akinwamide S O, Ajibola O O, Obadele B A, Olusunle S O, Olubambi P A, “Corrosion behavior of ductile and austempered ductile cast iron in 0.01M and 0.05M NaCl Environments”, Procedia Manufacturing, 30: 167-172, (2019).
  2. [2] Hsu C H, Chen M L, “Corrosion behavior of nickel alloyed and austempered ductile irons in 3.5% sodium chloride”, Corrosion Science, 52: 2945-2949, (2010).
  3. [3] Liu, J., Liu, H., Tian, X., Yang, H., Hao, J., “Microstructural evolution and corrosion properties of Ni-based alloy coatings fabricated by multi-layer laser cladding on cast iron”, Journal of Alloys and Compounds, 822: 1-11,(2020) 153708.
  4. [4] Cheng X, Hu S, Song W, Xiong X, “Improvement in corrosion resistance of a nodular cast iron surface modified by plasma beam treatment”, Applied Surface Science, 286: 334-343, (2013).
  5. [5] Benyounis K Y, Fakron O M A, Abboud J H, Olabi A G, Hashmi M J S, “Surface melting of nodular cast iron by Nd-YAG laser and TIG”, Journal of Materials Processing Technology, 170: 127-132, (2005).
  6. [6] Alabeedi K F, Abboud J H, Benyounis K Y, “Microstructure and erosion resistance enhancement of nodular cast iron by laser melting”, Wear, 266: 925-933, (2009).
  7. [7] Abboud J H, “Microstructure and erosion characteristic of nodular cast iron surface modified by tungsten inert gas”, Materials Design, 35: 677-684, (2012).
  8. [8] Guo Q, Zhong Y, Dong T, Gao P, Guo Y, Li J, “Effects of vermicular graphite rate on the oxidation resistance and mechanical properties of vermicular graphite iron”, Journal Alloys Compounds, 765: 213-220, (2018).

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mühendislik

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

1 Ekim 2022

Gönderilme Tarihi

24 Şubat 2021

Kabul Tarihi

9 Nisan 2021

Yayımlandığı Sayı

Yıl 2022 Cilt: 25 Sayı: 3

Kaynak Göster

APA
Hasırcı, H., Karacif, K., & Karatay, B. (2022). Effects of Vermiculariser, Inoculant and Copper Addition on Microstructure and Corrosion Properties of Vermicular Graphite Cast Iron. Politeknik Dergisi, 25(3), 1113-1121. https://doi.org/10.2339/politeknik.883279
AMA
1.Hasırcı H, Karacif K, Karatay B. Effects of Vermiculariser, Inoculant and Copper Addition on Microstructure and Corrosion Properties of Vermicular Graphite Cast Iron. Politeknik Dergisi. 2022;25(3):1113-1121. doi:10.2339/politeknik.883279
Chicago
Hasırcı, Hasan, Kubilay Karacif, ve Berkay Karatay. 2022. “Effects of Vermiculariser, Inoculant and Copper Addition on Microstructure and Corrosion Properties of Vermicular Graphite Cast Iron”. Politeknik Dergisi 25 (3): 1113-21. https://doi.org/10.2339/politeknik.883279.
EndNote
Hasırcı H, Karacif K, Karatay B (01 Ekim 2022) Effects of Vermiculariser, Inoculant and Copper Addition on Microstructure and Corrosion Properties of Vermicular Graphite Cast Iron. Politeknik Dergisi 25 3 1113–1121.
IEEE
[1]H. Hasırcı, K. Karacif, ve B. Karatay, “Effects of Vermiculariser, Inoculant and Copper Addition on Microstructure and Corrosion Properties of Vermicular Graphite Cast Iron”, Politeknik Dergisi, c. 25, sy 3, ss. 1113–1121, Eki. 2022, doi: 10.2339/politeknik.883279.
ISNAD
Hasırcı, Hasan - Karacif, Kubilay - Karatay, Berkay. “Effects of Vermiculariser, Inoculant and Copper Addition on Microstructure and Corrosion Properties of Vermicular Graphite Cast Iron”. Politeknik Dergisi 25/3 (01 Ekim 2022): 1113-1121. https://doi.org/10.2339/politeknik.883279.
JAMA
1.Hasırcı H, Karacif K, Karatay B. Effects of Vermiculariser, Inoculant and Copper Addition on Microstructure and Corrosion Properties of Vermicular Graphite Cast Iron. Politeknik Dergisi. 2022;25:1113–1121.
MLA
Hasırcı, Hasan, vd. “Effects of Vermiculariser, Inoculant and Copper Addition on Microstructure and Corrosion Properties of Vermicular Graphite Cast Iron”. Politeknik Dergisi, c. 25, sy 3, Ekim 2022, ss. 1113-21, doi:10.2339/politeknik.883279.
Vancouver
1.Hasan Hasırcı, Kubilay Karacif, Berkay Karatay. Effects of Vermiculariser, Inoculant and Copper Addition on Microstructure and Corrosion Properties of Vermicular Graphite Cast Iron. Politeknik Dergisi. 01 Ekim 2022;25(3):1113-21. doi:10.2339/politeknik.883279
 
TARANDIĞIMIZ DİZİNLER (ABSTRACTING / INDEXING)
181341319013191 13189 13187 13188 18016 

download Bu eser Creative Commons Atıf-AynıLisanslaPaylaş 4.0 Uluslararası ile lisanslanmıştır.