Araştırma Makalesi
BibTex RIS Kaynak Göster

Effect of Damping Ratios on the Seismic Behavior of a Historical Masonry Guesthouse Building

Yıl 2021, Cilt: 2 Sayı: 2, 60 - 71, 31.12.2021
https://doi.org/10.53501/rteufemud.1019237

Öz

The dynamic parameters obtained depending on the existing structural properties, material properties, boundary and damage condition are quite effective on the behavior of the structures under the effect of dynamic loads. These dynamic parameters have characteristic features for each structure. In this study, the effect of damping ratio, which is one of the dynamic characteristics, on the seismic behavior of historical structures was studied. For this aim, historical masonry Guesthouse Building belong to the Church of Santa Maria was selected to examined. Linear time history analyses were performed for three different damping ratios as 2%, 5%, and 10%. The horizontal component of Erzincan Earthquake (1992) was used in linear time history analyses. The maximum displacement, principal stress and strain values obtained from performed linear time history analyses for different damping ratios were compared. It is observed that, displacement, stress and strain values increase as the damping ratio decrease when the results are examined. It is concluded that, damping ratio is the important parameter for the evaluation of seismic response of historical masonry structures which are weak to external effect especially earthquake. Therefore, the damping ratios should be obtained with experimental tests before the numerical evaluation of seismic behavior.

Kaynakça

  • Abaqus (2016). Dassault systémes simulia corp. Providence: Rhode Island, USA.
  • Altunışık, A.C., Adanur, S., Genç, A.F., Günaydın, M. and Okur, F.Y. (2017). An investigation of the seismic behavior of an ancient masonry bastion using non-destructive and numerical methods, Experimental Mechanics, 57, 2, 245-259.
  • Altunışık, A.C., Adanur, S., Genç, A.F., Günaydın, M. and Okur, F.Y. (2016). Non-destructive testing of an ancient masonry bastion, Journal of Cultural Heritage, 22, 1049-1054.
  • Altunışık, A.C., Genç, A.F., Günaydin, M., Adanur, S. and Okur, F.Y. (2018). Ambient vibration-based system ıdentification of a medieval masonry bastion for health assessment using nonlinear analyses, International Journal of Nonlinear Sciences & Numerical Simulation, 19, 2, 107-124.
  • Benedetti, D., Carydis, P. and Pezzoli, P. (1998). Shaking table tests on 24 simple masonry buildings, Earthquake Engineering and Structural Dynamics, 27, 1, 67-90.
  • Gentile, C. and Saisi, A. (2007). Ambient vibration testing of historic masonry towers for structural identification and damage assessment, Construction and Building Materials, 21, 6, 1311-1321.
  • Juhásová, E., Sofronie, R. and Bairrão, R. (2008). Stone masonry in historical buildings-ways to increase their resistance and durability, Engineering Structures, 30, 8, 2194-2205.
  • Mazzon, N, Valluzzi, M.R., Aoki, T., Garbin, E., De Canio, G., Ranieri, N. and Modena, C. (2009). Shaking table tests on two multi-leaf stone masonry buildings, In: Proceeding of 11th Canadian Masonry Symposium, May 31st - June 3rd, Toronto, Canada.
  • Toker, S. and Ünay, A.İ. (2004) Mathematical modeling and finite element analysis of masonry arch bridges, Gazi University Journal of Science, 17, 2, 129-139.
  • Votsis, R.A., Kyriakides, N., Chrysostomou, C.Z., Tantele, E. and Demetriou, T. (2012). Ambient vibration testing of two masonry monuments in Cyprus, Soil Dynamics and Earthquake Engineering, 43, 58-68.

Effect of Damping Ratios on the Seismic Behavior of a Historical Masonry Guesthouse Building

Yıl 2021, Cilt: 2 Sayı: 2, 60 - 71, 31.12.2021
https://doi.org/10.53501/rteufemud.1019237

Öz

The dynamic parameters obtained depending on the existing structural properties, material properties, boundary and damage condition are quite effective on the behavior of the structures under the effect of dynamic loads. These dynamic parameters have characteristic features for each structure. In this study, the effect of damping ratio, which is one of the dynamic characteristics, on the seismic behavior of historical structures was studied. For this aim, historical masonry Guesthouse Building belong to the Church of Santa Maria was selected to examined. Linear time history analyses were performed for three different damping ratios as 2%, 5%, and 10%. The horizontal component of Erzincan Earthquake (1992) was used in linear time history analyses. The maximum displacement, principal stress and strain values obtained from performed linear time history analyses for different damping ratios were compared. It is observed that, displacement, stress and strain values increase as the damping ratio decrease when the results are examined. It is concluded that, damping ratio is the important parameter for the evaluation of seismic response of historical masonry structures which are weak to external effect especially earthquake. Therefore, the damping ratios should be obtained with experimental tests before the numerical evaluation of seismic behavior.

Kaynakça

  • Abaqus (2016). Dassault systémes simulia corp. Providence: Rhode Island, USA.
  • Altunışık, A.C., Adanur, S., Genç, A.F., Günaydın, M. and Okur, F.Y. (2017). An investigation of the seismic behavior of an ancient masonry bastion using non-destructive and numerical methods, Experimental Mechanics, 57, 2, 245-259.
  • Altunışık, A.C., Adanur, S., Genç, A.F., Günaydın, M. and Okur, F.Y. (2016). Non-destructive testing of an ancient masonry bastion, Journal of Cultural Heritage, 22, 1049-1054.
  • Altunışık, A.C., Genç, A.F., Günaydin, M., Adanur, S. and Okur, F.Y. (2018). Ambient vibration-based system ıdentification of a medieval masonry bastion for health assessment using nonlinear analyses, International Journal of Nonlinear Sciences & Numerical Simulation, 19, 2, 107-124.
  • Benedetti, D., Carydis, P. and Pezzoli, P. (1998). Shaking table tests on 24 simple masonry buildings, Earthquake Engineering and Structural Dynamics, 27, 1, 67-90.
  • Gentile, C. and Saisi, A. (2007). Ambient vibration testing of historic masonry towers for structural identification and damage assessment, Construction and Building Materials, 21, 6, 1311-1321.
  • Juhásová, E., Sofronie, R. and Bairrão, R. (2008). Stone masonry in historical buildings-ways to increase their resistance and durability, Engineering Structures, 30, 8, 2194-2205.
  • Mazzon, N, Valluzzi, M.R., Aoki, T., Garbin, E., De Canio, G., Ranieri, N. and Modena, C. (2009). Shaking table tests on two multi-leaf stone masonry buildings, In: Proceeding of 11th Canadian Masonry Symposium, May 31st - June 3rd, Toronto, Canada.
  • Toker, S. and Ünay, A.İ. (2004) Mathematical modeling and finite element analysis of masonry arch bridges, Gazi University Journal of Science, 17, 2, 129-139.
  • Votsis, R.A., Kyriakides, N., Chrysostomou, C.Z., Tantele, E. and Demetriou, T. (2012). Ambient vibration testing of two masonry monuments in Cyprus, Soil Dynamics and Earthquake Engineering, 43, 58-68.
Toplam 10 adet kaynakça vardır.

Ayrıntılar

Birincil Dil İngilizce
Konular Mühendislik
Bölüm Araştırma Makaleleri
Yazarlar

Ali Fuat Genç 0000-0002-2492-4019

Esin Ertürk 0000-0003-4053-0877

Ahmet Can Altunışık 0000-0002-2638-2903

Murat Günaydın 0000-0002-8549-2985

Fatih Yesevi Okur 0000-0003-2402-144X

Yayımlanma Tarihi 31 Aralık 2021
Yayımlandığı Sayı Yıl 2021 Cilt: 2 Sayı: 2

Kaynak Göster

APA Genç, A. F., Ertürk, E., Altunışık, A. C., Günaydın, M., vd. (2021). Effect of Damping Ratios on the Seismic Behavior of a Historical Masonry Guesthouse Building. Recep Tayyip Erdogan University Journal of Science and Engineering, 2(2), 60-71. https://doi.org/10.53501/rteufemud.1019237

Taranılan Dizinler

27717   22936   22937  22938   22939     22941   23010    23011   23019  23025