Araştırma Makalesi

Dimensional Accuracy of Conventional Impression Materials on Full-Arch Implant Impression

Cilt: 17 Sayı: 1 20 Nisan 2026
PDF İndir
TR EN

Dimensional Accuracy of Conventional Impression Materials on Full-Arch Implant Impression

Öz

Objective The purpose of this in vitro study was to compare conventional impression materials for close tray implant impressions of maxillary full arch with 5 implants. Material and Method The edentulous maxilla model and custom impression trays were fabricated from auto-polymerizing acrylic resin. 5 implant analogs (Moment Dental Implant Systems, Turkey) representing implants were placed in the midline on the edentulous maxilla model, on both sides canine and first molar region. The study consisted of 4 groups(n=10). Study groups were as follows: group C1 polyvinyl siloxane (Elite HD+ Tray Material; Zhermack Italy); C2 polyvinyl siloxane (Hydrorise Implant Heavy&Light NS; Zhermack, Italy); C3 condensation silicone (Zetaplus Putty and Oranwash L; Zhermack, Italy) and C4 polyether (3M ESPE (Soft) Monophase, USA). Conventional impressions were performed with custom-made close trays and casts were made by type IV dental stone. Casts were scanned with the laboratory-type scanner. Whether the data of four separate groups showed a normal distribution was analyzed at the significance level (p = 0.05) using one-way ANOVA analysis using the SPSS 27 program. Results According to one-way ANOVA analysis, the null hypothesis was rejected because the significant value was greater than 0.05, meaning one of the groups was different from the other. At the 99.2% significance level, it was determined that Group 4 had different characteristics from the other groups. Conclusion Polyvinyl siloxane impression material provides reliable results for impressions of implant-supported prostheses. Rigidity and polymerization shrinkage are thought to reduce the accuracy of polyether impression material.

Anahtar Kelimeler

Etik Beyan

“Tam Dişsiz Hastaların İmplantüstü Protezlerle Rehabilitasyonunda Kullanılan Geleneksel Ölçü Maddelerinin Boyutsal Stabilitesinin Değerlendirilmesi” (Dimensional Accuracy of Conventional Impression Materials on Full-Arch Implant Impression) başlıklı çalışmamız kapsamında gerçekleştirdiğimiz literatür taraması, insan ve hayvan sağlığı üzerinde herhangi bir risk oluşturmadığı ve sadece model üzerinde gerçekleştirilen bir çalışma olarak mevzuata uygun olarak yapıldığı için etik kurul iznine gerek duyulmamaktadır.Çalışmamız, herhangi bir kişi üzerinde deneysel bir müdahale içermemektedir. Bu bağlamda, çalışmanın etik kurul gerekliliği olmadığı kanaatindeyiz.

Kaynakça

  1. 1. Blatz MB, Conejo J. 2019.TheCurrentState of ChairsideDigitalDentistryandMaterials. DentClin North Am, 63(2):175-197.
  2. 2. Schmidt A, Wöstmann B, Schlenz MA. 2022.Accuracy of digitalimplantimpressions in clinicalstudies: A systematicreview. Clin Oral ImplantsRes, 33(6):573-585.
  3. 3. Tabesh M, Alikhasi M, Siadat H. 2018. A Comparison of implantimpressionprecision: Differentmaterialsandtechniques. J ClinExpDent, 10(2):e151-e157.
  4. 4. Tohme H, Lawand G, Chmielewska M, Makhzoume J. 2023.Comparisonbetweenstereophotogrammetric, digital, andconventionalimpressiontechniques in implant-supportedfixedcompletearchprostheses: An in vitrostudy. J ProsthetDent, 129(2):354-362.
  5. 5. Alsharbaty MHM, Alikhasi M, Zarrati S, Shamshiri AR. 2019. A ClinicalComparativeStudy of 3-Dimensional AccuracybetweenDigitalandConventionalImplantImpressionTechniques. J Prosthodont, 28(4):e902-e908.
  6. 6. Alikhasi M, Siadat H, Nasirpour A, Hasanzade M. 2018. Three-DimensionalAccuracy of DigitalImpressionversusConventionalMethod: Effect of ImplantAngulationand Connection Type. Int J Dent, 2018:3761750.
  7. 7. Siadat H, Saeidi Z, Alikhasi M, Zeighami S. 2018.Comparativeevaluation of theeffect of impressionmaterialsandtrays on theaccuracy of angulatedimplantsimpressions. J ClinExpDent, 1;10(11):e1096-e1102.
  8. 8. Punj A, Bompolaki D, Garaicoa J. 2017.DentalImpressionMaterialsandTechniques. DentClin North Am, 61(4):779-796.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Protez

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

20 Nisan 2026

Gönderilme Tarihi

24 Eylül 2024

Kabul Tarihi

13 Nisan 2026

Yayımlandığı Sayı

Yıl 2026 Cilt: 17 Sayı: 1

Kaynak Göster

APA
Koyu, T., Coşkun, A., Ulgey, M., & Gorler, O. (2026). Dimensional Accuracy of Conventional Impression Materials on Full-Arch Implant Impression. Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi, 17(1), 1-6. https://doi.org/10.22312/sdusbed.1555371
AMA
1.Koyu T, Coşkun A, Ulgey M, Gorler O. Dimensional Accuracy of Conventional Impression Materials on Full-Arch Implant Impression. Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi. 2026;17(1):1-6. doi:10.22312/sdusbed.1555371
Chicago
Koyu, Tuğçe, Akın Coşkun, Melih Ulgey, ve Oguzhan Gorler. 2026. “Dimensional Accuracy of Conventional Impression Materials on Full-Arch Implant Impression”. Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi 17 (1): 1-6. https://doi.org/10.22312/sdusbed.1555371.
EndNote
Koyu T, Coşkun A, Ulgey M, Gorler O (01 Nisan 2026) Dimensional Accuracy of Conventional Impression Materials on Full-Arch Implant Impression. Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi 17 1 1–6.
IEEE
[1]T. Koyu, A. Coşkun, M. Ulgey, ve O. Gorler, “Dimensional Accuracy of Conventional Impression Materials on Full-Arch Implant Impression”, Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi, c. 17, sy 1, ss. 1–6, Nis. 2026, doi: 10.22312/sdusbed.1555371.
ISNAD
Koyu, Tuğçe - Coşkun, Akın - Ulgey, Melih - Gorler, Oguzhan. “Dimensional Accuracy of Conventional Impression Materials on Full-Arch Implant Impression”. Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi 17/1 (01 Nisan 2026): 1-6. https://doi.org/10.22312/sdusbed.1555371.
JAMA
1.Koyu T, Coşkun A, Ulgey M, Gorler O. Dimensional Accuracy of Conventional Impression Materials on Full-Arch Implant Impression. Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi. 2026;17:1–6.
MLA
Koyu, Tuğçe, vd. “Dimensional Accuracy of Conventional Impression Materials on Full-Arch Implant Impression”. Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi, c. 17, sy 1, Nisan 2026, ss. 1-6, doi:10.22312/sdusbed.1555371.
Vancouver
1.Tuğçe Koyu, Akın Coşkun, Melih Ulgey, Oguzhan Gorler. Dimensional Accuracy of Conventional Impression Materials on Full-Arch Implant Impression. Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi. 01 Nisan 2026;17(1):1-6. doi:10.22312/sdusbed.1555371

CC

Creative Commons Attribution 4.0 International License

Atıf gereklidir, ticari olmayan amaçlarla kullanılabilir ve değişiklik yapılarak türev eser üretilemez.