Araştırma Makalesi

Shaping Ability of Reciprocating Single-file Systems in Simulated Canals: Reciproc versus Reciproc Blue

Cilt: 28 Sayı: 1 11 Mart 2021
PDF İndir
EN TR

Shaping Ability of Reciprocating Single-file Systems in Simulated Canals: Reciproc versus Reciproc Blue

Öz

The aim was to compare the canal straightening of M-wire [Reciproc (VDW, Munich, Germany)] and blue-wire heat-treated [Reciproc Blue (VDW) instruments in simulated resin L-shaped curved root canals. A total of 26 simulated L-shaped root canals with curvature of 45° and length of 17 mm (#15-0.02 taper) endo training blocks were divided into two groups (n = 13). All canals were prepared to an apical size 25 according to the manufacturers’ instructions. Pre- and post-instrumentation digital photography were superimposed and canal straightening was analysed using a computer imaging programme. Shapiro-Wilk test was used to determine the normal distribution of the data. For comparing two groups according to canal straightening independent t-test was used. During preparation no instrument fractured. All instruments maintained the original canal curvature well with no significant differences between the instruments. Regarding preparation time, no significant differences between the two instruments were obtained (P > 0.05). Under the conditions of this study, instruments were safe to use and all instruments respected the original canal curvature well. It was concluded that reciprocal motion files with or without blue-heat treated had similar preparation time and similar shaping abilities at intracanal temperature and maintained root canal curves equally well.

Anahtar Kelimeler

Destekleyen Kurum

Araştırmacılar çalışmayı kendıleri finanse etmiştir.

Kaynakça

  1. 1. Keskin C, Inan U, Demiral M, Keleş AJJoe. Cyclic fatigue resistance of Reciproc Blue, Reciproc, and WaveOne Gold reciprocating instruments. 2017;43(8):1360-3.
  2. 2. Pedullà E, Grande NM, Plotino G, Gambarini G, Rapisarda EJJoe. Influence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel-titanium rotary instruments. 2013;39(2):258-61.
  3. 3. Vahid A, Roohi N, Zayeri FJAEJ. A comparative study of four rotary NiTi instruments in preserving canal curvature, preparation time and change of working length. 2009;35(2):93-7.
  4. 4. Plotino G, Grande N, Testarelli L, Gambarini GJIEJ. Cyclic fatigue of Reciproc and WaveOne reciprocating instruments. 2012;45(7):614-8.
  5. 5. Kiefner P, Ban M, De‐Deus GJIej. Is the reciprocating movement per se able to improve the cyclic fatigue resistance of instruments? 2014;47(5):430-6.
  6. 6. Pedullà E, Grande NM, Plotino G, Gambarini G, Rapisarda E. Influence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel-titanium rotary instruments. Journal of endodontics. 2013;39(2):258-61.
  7. 7. Gambarini G, Gergi R, Naaman A, Osta N, Al Sudani D. Cyclic fatigue analysis of twisted file rotary NiTi instruments used in reciprocating motion. International endodontic journal. 2012;45(9):802-6.
  8. 8. Topçuoğlu H, Düzgün S, Aktı A, Topçuoğlu GJIej. Laboratory comparison of cyclic fatigue resistance of WaveOne Gold, Reciproc and WaveOne files in canals with a double curvature. 2017;50(7):713-7.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Diş Hekimliği

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

11 Mart 2021

Gönderilme Tarihi

11 Şubat 2021

Kabul Tarihi

16 Şubat 2021

Yayımlandığı Sayı

Yıl 2021 Cilt: 28 Sayı: 1

Kaynak Göster

APA
Çetinkaya, İ., & Başer Kolcu, M. İ. (2021). Shaping Ability of Reciprocating Single-file Systems in Simulated Canals: Reciproc versus Reciproc Blue. Medical Journal of Süleyman Demirel University, 28(1), 145-150. https://doi.org/10.17343/sdutfd.878545
AMA
1.Çetinkaya İ, Başer Kolcu Mİ. Shaping Ability of Reciprocating Single-file Systems in Simulated Canals: Reciproc versus Reciproc Blue. SDÜ Tıp Fak Derg. 2021;28(1):145-150. doi:10.17343/sdutfd.878545
Chicago
Çetinkaya, İrem, ve Mukadder İnci Başer Kolcu. 2021. “Shaping Ability of Reciprocating Single-file Systems in Simulated Canals: Reciproc versus Reciproc Blue”. Medical Journal of Süleyman Demirel University 28 (1): 145-50. https://doi.org/10.17343/sdutfd.878545.
EndNote
Çetinkaya İ, Başer Kolcu Mİ (01 Mart 2021) Shaping Ability of Reciprocating Single-file Systems in Simulated Canals: Reciproc versus Reciproc Blue. Medical Journal of Süleyman Demirel University 28 1 145–150.
IEEE
[1]İ. Çetinkaya ve M. İ. Başer Kolcu, “Shaping Ability of Reciprocating Single-file Systems in Simulated Canals: Reciproc versus Reciproc Blue”, SDÜ Tıp Fak Derg, c. 28, sy 1, ss. 145–150, Mar. 2021, doi: 10.17343/sdutfd.878545.
ISNAD
Çetinkaya, İrem - Başer Kolcu, Mukadder İnci. “Shaping Ability of Reciprocating Single-file Systems in Simulated Canals: Reciproc versus Reciproc Blue”. Medical Journal of Süleyman Demirel University 28/1 (01 Mart 2021): 145-150. https://doi.org/10.17343/sdutfd.878545.
JAMA
1.Çetinkaya İ, Başer Kolcu Mİ. Shaping Ability of Reciprocating Single-file Systems in Simulated Canals: Reciproc versus Reciproc Blue. SDÜ Tıp Fak Derg. 2021;28:145–150.
MLA
Çetinkaya, İrem, ve Mukadder İnci Başer Kolcu. “Shaping Ability of Reciprocating Single-file Systems in Simulated Canals: Reciproc versus Reciproc Blue”. Medical Journal of Süleyman Demirel University, c. 28, sy 1, Mart 2021, ss. 145-50, doi:10.17343/sdutfd.878545.
Vancouver
1.İrem Çetinkaya, Mukadder İnci Başer Kolcu. Shaping Ability of Reciprocating Single-file Systems in Simulated Canals: Reciproc versus Reciproc Blue. SDÜ Tıp Fak Derg. 01 Mart 2021;28(1):145-50. doi:10.17343/sdutfd.878545

Cited By

                                                                                         14791


Süleyman Demirel Üniversitesi Tıp Fakültesi Dergisi/Medical Journal of Süleyman Demirel University is licensed under Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International.