Araştırma Makalesi

Deterministic Lateral Displacement System with Inclined Elliptical Obstacles for Efficient Size-Based Separation of Microparticles

Cilt: 14 Sayı: 1 26 Mart 2025
PDF İndir
TR EN

Deterministic Lateral Displacement System with Inclined Elliptical Obstacles for Efficient Size-Based Separation of Microparticles

Öz

A deterministic lateral displacement system with inclined elliptical posts is demonstrated to sort spherical micrometer-sized solid particles. Numerical simulations via the finite-element method are performed to investigate the microfluidic system performance. Soft microparticles undergo deformations in designs with cylindrical posts or posts with sharp corners. Such deformations occur due to particle clogging between obstacles, which can disrupt the flow lanes. The proposed approach aims to eliminate these challenges. The calculations reveal a much-reduced rate of change in flow velocity between vertically inclined elliptical posts, compared to circular posts. The calculated critical particle sizes are more likely to follow the equation associated with the first flow lane width derived from a parabolic velocity profile at high fluid inlet rates, rather than the two semi-analytical models proposed for circular posts. The experimental and theoretical critical diameter data exhibited greater agreement with the critical diameter equation obtained using the curve-fitting method at lower fluid inlet rates. Overall, the minimum particle size decreased as the rate of flow increased. When assessing the connection between the two, a smaller critical diameter is achieved by decreasing the inclination angle. The adjustability of the system by rotating the posts is a major advantage of the proposed approach.

Anahtar Kelimeler

Destekleyen Kurum

TÜBİTAK

Proje Numarası

117F403

Kaynakça

  1. Whitesides GM. The origins and the future of microfluidics. Nature. 2006;442(7101):368-73.
  2. Yager P, Edwards T, Fu E, Helton K, Nelson K, Tam MR, Weigl BH. Microfluidic diagnostic technologies for global public health. Nature. 2006;442(7101):412-8.
  3. Salafi T, Zeming KK, Zhang Y. Advancements in microfluidics for nanoparticle separation. Lab on a Chip. 2017;17(1):11-33.
  4. Xu X, Sarder P, Kotagiri N, Achilefu S, Nehorai A. Performance analysis and design of position-encoded microsphere arrays using the Ziv-Zakai bound. IEEE Transactions on Nanobioscience. 2012;12(1):29-40.
  5. Choi J-W, Oh KW, Thomas JH, Heineman WR, Halsall HB, Nevin JH, et al. An integrated microfluidic biochemical detection system for protein analysis with magnetic bead-based sampling capabilities. Lab on a Chip. 2002;2(1):27-30.
  6. Dittrich PS, Schwille P. An integrated microfluidic system for reaction, high-sensitivity detection, and sorting of fluorescent cells and particles. Analytical chemistry. 2003;75(21):5767-74.
  7. Munaz A, Shiddiky MJ, Nguyen N-T. Recent advances and current challenges in magnetophoresis based micro magnetofluidics. Biomicrofluidics. 2018;12(3).
  8. Jubery TZ, Srivastava SK, Dutta P. Dielectrophoretic separation of bioparticles in microdevices: A review. Electrophoresis. 2014;35(5):691-713.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Yoğun Madde Fiziği (Diğer), Mikroakışkanlar ve Nanoakışkanlar

Bölüm

Araştırma Makalesi

Erken Görünüm Tarihi

26 Mart 2025

Yayımlanma Tarihi

26 Mart 2025

Gönderilme Tarihi

22 Ağustos 2024

Kabul Tarihi

7 Mart 2025

Yayımlandığı Sayı

Yıl 2025 Cilt: 14 Sayı: 1

Kaynak Göster

APA
Sayarcan, D., Çiçek, A., & Körözlü, N. (2025). Deterministic Lateral Displacement System with Inclined Elliptical Obstacles for Efficient Size-Based Separation of Microparticles. Türk Doğa ve Fen Dergisi, 14(1), 197-203. https://doi.org/10.46810/tdfd.1537189
AMA
1.Sayarcan D, Çiçek A, Körözlü N. Deterministic Lateral Displacement System with Inclined Elliptical Obstacles for Efficient Size-Based Separation of Microparticles. TDFD. 2025;14(1):197-203. doi:10.46810/tdfd.1537189
Chicago
Sayarcan, Döne, Ahmet Çiçek, ve Nurettin Körözlü. 2025. “Deterministic Lateral Displacement System with Inclined Elliptical Obstacles for Efficient Size-Based Separation of Microparticles”. Türk Doğa ve Fen Dergisi 14 (1): 197-203. https://doi.org/10.46810/tdfd.1537189.
EndNote
Sayarcan D, Çiçek A, Körözlü N (01 Mart 2025) Deterministic Lateral Displacement System with Inclined Elliptical Obstacles for Efficient Size-Based Separation of Microparticles. Türk Doğa ve Fen Dergisi 14 1 197–203.
IEEE
[1]D. Sayarcan, A. Çiçek, ve N. Körözlü, “Deterministic Lateral Displacement System with Inclined Elliptical Obstacles for Efficient Size-Based Separation of Microparticles”, TDFD, c. 14, sy 1, ss. 197–203, Mar. 2025, doi: 10.46810/tdfd.1537189.
ISNAD
Sayarcan, Döne - Çiçek, Ahmet - Körözlü, Nurettin. “Deterministic Lateral Displacement System with Inclined Elliptical Obstacles for Efficient Size-Based Separation of Microparticles”. Türk Doğa ve Fen Dergisi 14/1 (01 Mart 2025): 197-203. https://doi.org/10.46810/tdfd.1537189.
JAMA
1.Sayarcan D, Çiçek A, Körözlü N. Deterministic Lateral Displacement System with Inclined Elliptical Obstacles for Efficient Size-Based Separation of Microparticles. TDFD. 2025;14:197–203.
MLA
Sayarcan, Döne, vd. “Deterministic Lateral Displacement System with Inclined Elliptical Obstacles for Efficient Size-Based Separation of Microparticles”. Türk Doğa ve Fen Dergisi, c. 14, sy 1, Mart 2025, ss. 197-03, doi:10.46810/tdfd.1537189.
Vancouver
1.Döne Sayarcan, Ahmet Çiçek, Nurettin Körözlü. Deterministic Lateral Displacement System with Inclined Elliptical Obstacles for Efficient Size-Based Separation of Microparticles. TDFD. 01 Mart 2025;14(1):197-203. doi:10.46810/tdfd.1537189