Protection of Reinforced Concrete Columns from Pounding-Induced Effects in Adjacent Buildings

Cilt: 35 Sayı: 3 1 Mayıs 2024
PDF İndir
EN TR

Protection of Reinforced Concrete Columns from Pounding-Induced Effects in Adjacent Buildings

Öz

The pounding damage is one of the most common seismic damages observed after past earthquakes in adjacent reinforced concrete (RC) buildings having insufficient gap in-between. Particularly in highly populated regions, there are numerous adjacent RC buildings, in which pounding can cause severe damage or total collapse. Many previous reconnaissance reports following earthquakes have emphasized severe column damage due to pounding with the slab of adjacent building. In this paper, a retrofitting method is presented to reduce the seismic damage caused by pounding on existing RC structural elements in cases where collision is unavoidable. Pounding effects are investigated by using 4- and 7-story RC buildings with unequal floor elevations. As a retrofitting solution for pounding, steel columns and neoprene rubber pads are placed at the mid-height of the story so that the pounding takes place between the neighboring slab and added steel columns instead of existing RC columns. The mid-column pounding of existing RC buildings with and without retrofitting are numerically investigated. In the numerical model, buildings are connected by link elements to reproduce the pounding in-between. Nonlinear response history analyses are performed using 11 different real ground-motion records. Pounding forces, peak floor accelerations, inter-story drift ratios, story shear force distributions, and plastic hinge distributions are obtained and compared for each of the pounding conditions. The analysis results revealed that the proposed retrofitting method protects the existing RC columns from brittle type of shear failure and reduces the destructive effects of pounding.

Anahtar Kelimeler

Destekleyen Kurum

The Scientific and Technological Research Council of Turkey (TÜBİTAK)

Proje Numarası

120M877

Teşekkür

This work was supported by The Scientific and Technological Research Council of Turkey (TÜBİTAK) [grant number 120M877]

Kaynakça

  1. Maison BF, Kasai K. Analysis for a Type of Structural Pounding. J Struct Eng 1990; 116(4):957–77.
  2. Anagnostopoulos SA, Spiliopoulos KV. An investigation of earthquake induced pounding between adjacent buildings. Earthq Eng Struct Dyn 1992;21:289–302.
  3. TBEC-2018. Turkish Building Earthquake Code. Ankara, Turkey: 2018.
  4. Jeng V, Kasai K, Maison BF. A Spectral Difference Method to Estimate Building Separations to Avoid Pounding. Earthq Spectra 1992;8:201–23. https://doi.org/10.1193/1.1585679.
  5. Kamal M, Inel M. Simplified approaches for estimation of required seismic separation distance between adjacent reinforced concrete buildings. Eng Struct 2021:113610. https://doi.org/10.1016/j.engstruct.2021.113610.
  6. Favvata MJ. Minimum required separation gap for adjacent RC frames with potential inter-story seismic pounding. Eng Struct 2017;152:643–59. https://doi.org/10.1016/j.engstruct.2017.09.025.
  7. Kamal M, Code-based new approaches for determining the minimum required separation gap. Structures 2022;46:750-764. https://doi.org/10.1016/j.istruc.2022.10.075.
  8. Khatami SM, Naderpour H, Razavi SMN, Barros RC, Sołtysik B, Jankowski R. An ANN-Based Approach for Prediction of Sufficient Seismic Gap between Adjacent Buildings Prone to Earthquake-Induced Pounding. Applied Sciences 2020;10:3591. https://doi.org/10.3390/app10103591.

Ayrıntılar

Birincil Dil

İngilizce

Konular

İnşaat Mühendisliği

Bölüm

Araştırma Makalesi

Erken Görünüm Tarihi

4 Ocak 2024

Yayımlanma Tarihi

1 Mayıs 2024

Gönderilme Tarihi

10 Nisan 2023

Kabul Tarihi

22 Aralık 2023

Yayımlandığı Sayı

Yıl 2024 Cilt: 35 Sayı: 3

Kaynak Göster

APA
Altan Oymanlı, S., & Avşar, Ö. (2024). Protection of Reinforced Concrete Columns from Pounding-Induced Effects in Adjacent Buildings. Turkish Journal of Civil Engineering, 35(3), 47-70. https://doi.org/10.18400/tjce.1280691
AMA
1.Altan Oymanlı S, Avşar Ö. Protection of Reinforced Concrete Columns from Pounding-Induced Effects in Adjacent Buildings. tjce. 2024;35(3):47-70. doi:10.18400/tjce.1280691
Chicago
Altan Oymanlı, Sueda, ve Özgür Avşar. 2024. “Protection of Reinforced Concrete Columns from Pounding-Induced Effects in Adjacent Buildings”. Turkish Journal of Civil Engineering 35 (3): 47-70. https://doi.org/10.18400/tjce.1280691.
EndNote
Altan Oymanlı S, Avşar Ö (01 Mayıs 2024) Protection of Reinforced Concrete Columns from Pounding-Induced Effects in Adjacent Buildings. Turkish Journal of Civil Engineering 35 3 47–70.
IEEE
[1]S. Altan Oymanlı ve Ö. Avşar, “Protection of Reinforced Concrete Columns from Pounding-Induced Effects in Adjacent Buildings”, tjce, c. 35, sy 3, ss. 47–70, May. 2024, doi: 10.18400/tjce.1280691.
ISNAD
Altan Oymanlı, Sueda - Avşar, Özgür. “Protection of Reinforced Concrete Columns from Pounding-Induced Effects in Adjacent Buildings”. Turkish Journal of Civil Engineering 35/3 (01 Mayıs 2024): 47-70. https://doi.org/10.18400/tjce.1280691.
JAMA
1.Altan Oymanlı S, Avşar Ö. Protection of Reinforced Concrete Columns from Pounding-Induced Effects in Adjacent Buildings. tjce. 2024;35:47–70.
MLA
Altan Oymanlı, Sueda, ve Özgür Avşar. “Protection of Reinforced Concrete Columns from Pounding-Induced Effects in Adjacent Buildings”. Turkish Journal of Civil Engineering, c. 35, sy 3, Mayıs 2024, ss. 47-70, doi:10.18400/tjce.1280691.
Vancouver
1.Sueda Altan Oymanlı, Özgür Avşar. Protection of Reinforced Concrete Columns from Pounding-Induced Effects in Adjacent Buildings. tjce. 01 Mayıs 2024;35(3):47-70. doi:10.18400/tjce.1280691

Cited By