Effect of Dental Implant Dimensions on Fatigue Behaviour: A Numerical Approach
Öz
Anahtar Kelimeler
Kaynakça
- Ao J., Li T., Liu Y., Ding Y., Wu G., Hua K., Kong L. Optimal design of thread height and width on an immediately loaded cylinder implant: A finite element analysis, Computers in Biology and Medicine 2010; 40: 681-686 doi:10.1016/j.compbiomed.2009.10.007.
- Ausiello P., Franciosa P., Martorelli M.,Watts D.C. Effects of thread features in osseo-integrated titanium implants using a statistics-based finite element method. Dental Materials 2012; 28: 919-927. doi: 10.1016/j.dental.2012.04.035
- Barbier L., Vander Sloten J., Krzesinski G., Schepers E., Van Der Perre G. Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog. Journal of Oral Rehabilitation.1998;25:847-858.doi: 10.1046/j.13652842.1998.00318.x
- Chun H-J., S.-Y. Cheong S-Y., Han J-H., Heo S-J., Chung J-P., Rhyu I-C., Choı Y-C., Baik H-K., Ku Y. ve Kım M-H. Evaluation of design parameters of osseointegrated dental implants using finite element analysis. Journal of Oral Rehabilitation 2002; 29: 565–574. doi: 10.1046/j.1365-2842.2002.00891.x
- Daas, M., Dubois, G., Bonnet, A. S., Lipinski, P., Rignon-Bret, C. A complete finite element 224 model of a mandibular implant retained overdenture with two implants: Comparison between rigid and 225 resilient attachment configurations. Medical Engineering & Physics 2008; 30: 218-225. doi: 10.1016/j.medengphy.2007.02.005
- Dilek O., Tezulas E., Dincel M. Required minimum primary stability and torque values for immediate loading of mini dentalimplants: an experimentalstudy in nonviable bovine femoral bone. Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology 2008; 105: 20-27. doi: 10.1016/j.tripleo.2007.10.003.
- Dittmer S., Dittmer M.P., Kohorst P., Jendras M., Borchers L., Stiesch M. Effect of implant–abutment connection design on load bearing capacity and failure mode of implants. Journal of Prosthodontics 2011; 20: 510-516. doi: 10.1111/j.1532-849X.2011.00758.x
- Djebbar N., Serier B., Bachir Bouiadjra B., Benbarek S., Drai A. Analysis of the effect of load direction on the stress distribution in dental implant. Materials & Design 2010; 31: 2097-2101. doi: 10.1016/j.matdes.2009.10.042
Ayrıntılar
Birincil Dil
İngilizce
Konular
Mühendislik
Bölüm
Araştırma Makalesi
Yayımlanma Tarihi
31 Aralık 2018
Gönderilme Tarihi
24 Mart 2017
Kabul Tarihi
30 Kasım 2018
Yayımlandığı Sayı
Yıl 2018 Cilt: 23 Sayı: 3
Cited By
A comprehensive review of factors affecting fatigue life of dental implants
Materials Today: Proceedings
https://doi.org/10.1016/j.matpr.2020.08.414Stress Distribution Around Two Dental Implant Materials with New Designs: Comparative Finite Element Analysis Study
Indonesian Journal of Dental Medicine
https://doi.org/10.20473/ijdm.v4i1.2021.19-25Effect of the geometry of butt-joint implant-supported restorations on the fatigue life of prosthetic screws
The Journal of Prosthetic Dentistry
https://doi.org/10.1016/j.prosdent.2021.12.010Crack initiation and growth simulations of functionally graded dental implant subjected to cyclic axial loads
Fatigue & Fracture of Engineering Materials & Structures
https://doi.org/10.1111/ffe.13802