Konvansiyonel Baş-Boyun Radyoterapisinde Dozimetrik Sürecin Termolüminisans Dozimetre ile Kontrolü

Cilt: 37 Sayı: 3 1 Eylül 2011
  • Ali Altay
  • Abdullah Yeşil
  • Sema Gözcü
  • Sonay Arslan
  • Oya Karadağ
  • Gökay Kaynak
  • Lütfi Özkan
  • Candan Demiröz
PDF İndir
EN TR

Control of the Dosimetric Process at Conventional Head and Neck Radiotherapy with Thermo Luminescence Dosimeter

Öz

In this study, our purpose is to control dosimetric process of head and neck radiotherapy technique with ThermoLuminescence Dosimeters (TLD). Dosimetric equipment, treatment devices and randofantom were used in the study. At treatment position, cross-sectional areas of randophantom screened with Computerized Tomography-Simulator. Radiotherapy fields identified at virtual simulation. Radiographs from simulation transferred to Computerized Treatment Planning System (CTPS) to control the fields and then point doses calculated. TLDs were placed to determined points at the randophantom then irradiation applied for 5 times to get average values of measurement. Target volume and critical organ doses were evaluated. Difference between the CTPS and measured doses lower than ±%5 was taken in the acceptable limit. The mean of measured doses from 2 points at the target volume were 203,5cGy and mean of calculated CTPS doses were 207cGy. The difference was below %2. Maximum difference of measured and calculated doses at supraclavicular and lateral field junction plane is %3,49. At the lymph node regions, which are within planning treatment volume, the maximum difference was %3,59. In this study, even if results were in the acceptable margin, controlling the CTPS algorithm and treatment period with TLD dosimeters is not ideal, but, useful for all levels.

Anahtar Kelimeler

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

-

Yazarlar

Abdullah Yeşil Bu kişi benim

Sema Gözcü Bu kişi benim

Sonay Arslan Bu kişi benim

Oya Karadağ Bu kişi benim

Gökay Kaynak Bu kişi benim

Lütfi Özkan Bu kişi benim

Candan Demiröz Bu kişi benim

Yayımlanma Tarihi

1 Eylül 2011

Gönderilme Tarihi

1 Eylül 2011

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2011 Cilt: 37 Sayı: 3

Kaynak Göster

APA
Altay, A., Yeşil, A., Gözcü, S., Arslan, S., Karadağ, O., Kaynak, G., Özkan, L., & Demiröz, C. (2011). Control of the Dosimetric Process at Conventional Head and Neck Radiotherapy with Thermo Luminescence Dosimeter. Journal of Uludağ University Medical Faculty, 37(3), 117-122. https://izlik.org/JA57WP28TN
AMA
1.Altay A, Yeşil A, Gözcü S, vd. Control of the Dosimetric Process at Conventional Head and Neck Radiotherapy with Thermo Luminescence Dosimeter. Uludağ Tıp Derg. 2011;37(3):117-122. https://izlik.org/JA57WP28TN
Chicago
Altay, Ali, Abdullah Yeşil, Sema Gözcü, vd. 2011. “Control of the Dosimetric Process at Conventional Head and Neck Radiotherapy with Thermo Luminescence Dosimeter”. Journal of Uludağ University Medical Faculty 37 (3): 117-22. https://izlik.org/JA57WP28TN.
EndNote
Altay A, Yeşil A, Gözcü S, Arslan S, Karadağ O, Kaynak G, Özkan L, Demiröz C (01 Eylül 2011) Control of the Dosimetric Process at Conventional Head and Neck Radiotherapy with Thermo Luminescence Dosimeter. Journal of Uludağ University Medical Faculty 37 3 117–122.
IEEE
[1]A. Altay vd., “Control of the Dosimetric Process at Conventional Head and Neck Radiotherapy with Thermo Luminescence Dosimeter”, Uludağ Tıp Derg, c. 37, sy 3, ss. 117–122, Eyl. 2011, [çevrimiçi]. Erişim adresi: https://izlik.org/JA57WP28TN
ISNAD
Altay, Ali - Yeşil, Abdullah - Gözcü, Sema - Arslan, Sonay - Karadağ, Oya - Kaynak, Gökay - Özkan, Lütfi - Demiröz, Candan. “Control of the Dosimetric Process at Conventional Head and Neck Radiotherapy with Thermo Luminescence Dosimeter”. Journal of Uludağ University Medical Faculty 37/3 (01 Eylül 2011): 117-122. https://izlik.org/JA57WP28TN.
JAMA
1.Altay A, Yeşil A, Gözcü S, Arslan S, Karadağ O, Kaynak G, Özkan L, Demiröz C. Control of the Dosimetric Process at Conventional Head and Neck Radiotherapy with Thermo Luminescence Dosimeter. Uludağ Tıp Derg. 2011;37:117–122.
MLA
Altay, Ali, vd. “Control of the Dosimetric Process at Conventional Head and Neck Radiotherapy with Thermo Luminescence Dosimeter”. Journal of Uludağ University Medical Faculty, c. 37, sy 3, Eylül 2011, ss. 117-22, https://izlik.org/JA57WP28TN.
Vancouver
1.Ali Altay, Abdullah Yeşil, Sema Gözcü, Sonay Arslan, Oya Karadağ, Gökay Kaynak, Lütfi Özkan, Candan Demiröz. Control of the Dosimetric Process at Conventional Head and Neck Radiotherapy with Thermo Luminescence Dosimeter. Uludağ Tıp Derg [Internet]. 01 Eylül 2011;37(3):117-22. Erişim adresi: https://izlik.org/JA57WP28TN

ISSN: 1300-414X, e-ISSN: 2645-9027

Uludağ Üniversitesi Tıp Fakültesi Dergisi "Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License" ile lisanslanmaktadır.


Creative Commons License
Journal of Uludag University Medical Faculty is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

2023