Araştırma Makalesi

The Effects of Ultrasound Times and Amplitudes on the Particle Size and Emulsifying Properties of Whey Protein Concentrate

Cilt: 27 Sayı: 2 30 Ağustos 2022
PDF İndir
TR EN

The Effects of Ultrasound Times and Amplitudes on the Particle Size and Emulsifying Properties of Whey Protein Concentrate

Öz

The current study was conducted to investigate the effects of ultrasound times and amplitudes on the particle sizes and emulsifying properties of samples of whey protein concentrate (WPC). The ultrasound (US) application was performed using VC-7500 ultrasonic power equipment at a 20 kHz frequency, at various times (10, 20, and 30 min at a 50% amplitude) and amplitudes (60%, 80%, and 100% for 5 min). The results showed that the US procedure had a significant effect (p<0.05) on both particle sizes and emulsifying properties (p<0.05). The smallest particle size was obtained for the WPC samples exposed to 30 min of US at a 100% amplitude (US310) (498.6 nm). The WPC samples treated at a 100% amplitude showed a smaller particle size compared to the other WPC samples at 60% and 80% amplitudes. While the WPC samples treated for 10 min had the biggest particle size (790.3 nm), those treated for 30 min had the smallest particle size (697.1 nm). On the other hand, among the treatments, US310 whey protein concentrate samples had the highest EAI (emulsifying activity index) (198 m2/g) and ESI (emulsion stability index) (34.0 min), whereas the untreated WPC samples had the lowest EAI (56 m2/g) and ESI (13.0 min). In general, 30-min US treatment at a 100% amplitude showed the lowest particle size (498.6 nm) and the highest emulsifying properties (EAI: 198 m2/g and ESI: 34.0) compared to the other sonication times and amplitudes.

Anahtar Kelimeler

Amplitude, Emulsifying properties, Particle size, Ultrasound, Whey protein concentrate

Kaynakça

  1. Abd El-Salam, M. H., El-Shibiny, S., & Salem, A. (2009). Factors affecting the functional properties of whey protein products: A review. Food Reviews International, 25(3), 251-270. doi:10.1080/87559120902956224
  2. Arzeni, C., Martinez, K., Zema, P., Arias, A., Perez, O. E., & Pilosof, A. M. R. (2012). Comparative study of high intensity ultrasound effects on food proteins functionality. Journal of Food Engineering, 108, 463-472. doi:10.1016/j.jfoodeng.2011.08.018
  3. Gordon, L., & Pilosof, A. M. (2010). Application of high-intensity ultrasounds to control the size of whey proteins particles. Food Biophysics, 5(3), 203-210. doi: 10.1007/s11483-010-9161-4
  4. Jambrak, A. R., Mason, T. M., Lelas, V., Herceg, Z., & Herceg, I. L. (2008). Effect of ultrasound treatment on solubility & foaming properties of whey protein suspensions. Journal of Food Engineering, 86, 281–287. doi:10.1016/j.jfoodeng.2007.10.004
  5. Jambrak, A. R., Mason, T. J., Lelas, V., Paniwnyk, L., & Herceg, Z. (2014). Effect of ultrasound treatment on particle size & molecular weight of whey proteins. Journal of Food Engineering, 121, 15-23. doi:10.1016/j.jfoodeng.2013.08.012
  6. Jiang, S., Yıldız, G., Ding, J., Andrade, J., Rababah, T. M., Almajwalc, A., Abulmeatyc, M. M., & Feng, H. (2019). Pea protein nanoemulsion and nanocomplex as carriers for protection of cholecalciferol (vitamin D3). Food and Bioprocess Technology, 12(6), 1031-1040. doi:10.1007/s11947-019-02276-0
  7. Karki, B., Lamsal, B. P., Jung, S., van Leeuwen, J. H., Pometto III, A. L., Grewell, D., & Khanal, S. K. (2010). Enhancing protein and sugar release from defatted soy flakes using ultrasound technology. Journal of Food Engineering, 96(2), 270-278. doi:10.1016/j.jfoodeng.2009.07.023
  8. Krešić, G., Lelas, V., Jambrak, A. R., Herceg, Z., & Brnčić, S. R. (2008). Influence of novel food processing technologies on the rheological & thermophysical properties of whey proteins. Journal of Food Engineering, 87(1), 64–73. doi:10.1016%2Fj.jfoodeng.2007.10.024
  9. Kumar, R., Chauhan, S. K., Shinde, G., Subramanian, V., & Nadanasabapathi, S. (2018). Whey Proteins: A potential ingredient for food industry- A review. Asian Journal of Dairy and Food Research, 37, 283-290. doi:10.18805/ajdfr.DR-1389
  10. Lam, R. (2014). Tailoring of whey protein isoalte stabilized oil-water interfaces for improved emulsification. (PhD), Saskatchewan University, Department of Food and Bioproduct Sciences Saskatoon, SK.

Kaynak Göster

APA
Bulut, M. (2022). The Effects of Ultrasound Times and Amplitudes on the Particle Size and Emulsifying Properties of Whey Protein Concentrate. Yüzüncü Yıl Üniversitesi Fen Bilimleri Enstitüsü Dergisi, 27(2), 323-329. https://doi.org/10.53433/yyufbed.1077700
AMA
1.Bulut M. The Effects of Ultrasound Times and Amplitudes on the Particle Size and Emulsifying Properties of Whey Protein Concentrate. YYUFBED. 2022;27(2):323-329. doi:10.53433/yyufbed.1077700
Chicago
Bulut, Menekşe. 2022. “The Effects of Ultrasound Times and Amplitudes on the Particle Size and Emulsifying Properties of Whey Protein Concentrate”. Yüzüncü Yıl Üniversitesi Fen Bilimleri Enstitüsü Dergisi 27 (2): 323-29. https://doi.org/10.53433/yyufbed.1077700.
EndNote
Bulut M (01 Ağustos 2022) The Effects of Ultrasound Times and Amplitudes on the Particle Size and Emulsifying Properties of Whey Protein Concentrate. Yüzüncü Yıl Üniversitesi Fen Bilimleri Enstitüsü Dergisi 27 2 323–329.
IEEE
[1]M. Bulut, “The Effects of Ultrasound Times and Amplitudes on the Particle Size and Emulsifying Properties of Whey Protein Concentrate”, YYUFBED, c. 27, sy 2, ss. 323–329, Ağu. 2022, doi: 10.53433/yyufbed.1077700.
ISNAD
Bulut, Menekşe. “The Effects of Ultrasound Times and Amplitudes on the Particle Size and Emulsifying Properties of Whey Protein Concentrate”. Yüzüncü Yıl Üniversitesi Fen Bilimleri Enstitüsü Dergisi 27/2 (01 Ağustos 2022): 323-329. https://doi.org/10.53433/yyufbed.1077700.
JAMA
1.Bulut M. The Effects of Ultrasound Times and Amplitudes on the Particle Size and Emulsifying Properties of Whey Protein Concentrate. YYUFBED. 2022;27:323–329.
MLA
Bulut, Menekşe. “The Effects of Ultrasound Times and Amplitudes on the Particle Size and Emulsifying Properties of Whey Protein Concentrate”. Yüzüncü Yıl Üniversitesi Fen Bilimleri Enstitüsü Dergisi, c. 27, sy 2, Ağustos 2022, ss. 323-9, doi:10.53433/yyufbed.1077700.
Vancouver
1.Menekşe Bulut. The Effects of Ultrasound Times and Amplitudes on the Particle Size and Emulsifying Properties of Whey Protein Concentrate. YYUFBED. 01 Ağustos 2022;27(2):323-9. doi:10.53433/yyufbed.1077700