Araştırma Makalesi

Investigation of radiosensitivity of gamma irradiated procaine hydrochloride in the solid state

Cilt: 4 Sayı: 3 30 Eylül 2017
PDF İndir
EN TR

Investigation of radiosensitivity of gamma irradiated procaine hydrochloride in the solid state

Öz

Dosimetric properties of gamma-irradiated procaine hydrochloride were investigated at room temperature by Electron Paramagnetic Resonance technique. No signal was obtained on the non-irradiated samples; however significant signals were obtained from the samples irradiated with gamma at certain doses.  Mathematical functions and correlation coefficients were calculated determining the relation between the increasing radiation doses on the signal intensities of the sample. The free radicals were appeared to be stable at room temperature for more than 200 days. 

Anahtar Kelimeler

Kaynakça

  1. [1] Crucq, A.S., Slegers, C., Deridder, V., Tilquin, B., 2000, Radiosensitivity study of cefazolin sodium. Talanta, 52, 873-877.
  2. [2] Sütçü, K., Osmanoğlu, Y.E., Akbalık, F., 2016, Investigation of radiosensitivity of gamma irradiated isoniazid antibiotic through epr spectroscopy. Anadolu Unv. J. Sci. Tech. A, 17, 735-740.
  3. [3] Desroisers, M.C., 1996, Current status of the EPR method to detect irradiated food. Appl. Radiat. Isot., 47, 1621-1628.
  4. [4] Petrişor, D., Damian, G., Simon, S., 2008, Gamma-irradiated ExtraVit M nutritive supplement studied by electron paramagnetic resonance spectroscopy. Radiat. Phys. Chem., 77, 463-468.
  5. [5] Sütçü, K., Osmanoğlu, Y.E., 2017, The effect of gamma radiation on some succinic acid derivatives in the solid state. J. Mol. Struct., 1127, 476-478.
  6. [6] Osmanoğlu, Y.E., Sütçü, K., 2017, EPR studies of the free radicals generated in gamma irradiated amino acid derivatives. J. Mol. Struct., 1145, 240-243.
  7. [7] Basly, J.P., Longy, I., Bernard, M., 1997, Influence of radiation treatment on two antibacterial agents and four antiprotozoal agents: ESR dosimetry. Int. J. Pharma., 154, 109-113.
  8. [8] Basly, J.P., Bernard, M., 1997, Radio sterilization dosimetry by ESR spectroscopy: Ritodrine hydrochloride and comparison with other sympathomimetics. Int. J. Pharma., 149, 85-91.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mühendislik

Bölüm

Araştırma Makalesi

Yazarlar

Şemsettin Osmanoğlu
DİCLE ÜNİVERSİTESİ
Türkiye

Yayımlanma Tarihi

30 Eylül 2017

Gönderilme Tarihi

4 Mayıs 2017

Kabul Tarihi

-

Yayımlandığı Sayı

Yıl 2017 Cilt: 4 Sayı: 3

Kaynak Göster

APA
Osmanoğlu, Ş. (2017). Investigation of radiosensitivity of gamma irradiated procaine hydrochloride in the solid state. El-Cezeri, 4(3), 314-318. https://doi.org/10.31202/ecjse.310494
AMA
1.Osmanoğlu Ş. Investigation of radiosensitivity of gamma irradiated procaine hydrochloride in the solid state. ECJSE. 2017;4(3):314-318. doi:10.31202/ecjse.310494
Chicago
Osmanoğlu, Şemsettin. 2017. “Investigation of radiosensitivity of gamma irradiated procaine hydrochloride in the solid state”. El-Cezeri 4 (3): 314-18. https://doi.org/10.31202/ecjse.310494.
EndNote
Osmanoğlu Ş (01 Eylül 2017) Investigation of radiosensitivity of gamma irradiated procaine hydrochloride in the solid state. El-Cezeri 4 3 314–318.
IEEE
[1]Ş. Osmanoğlu, “Investigation of radiosensitivity of gamma irradiated procaine hydrochloride in the solid state”, ECJSE, c. 4, sy 3, ss. 314–318, Eyl. 2017, doi: 10.31202/ecjse.310494.
ISNAD
Osmanoğlu, Şemsettin. “Investigation of radiosensitivity of gamma irradiated procaine hydrochloride in the solid state”. El-Cezeri 4/3 (01 Eylül 2017): 314-318. https://doi.org/10.31202/ecjse.310494.
JAMA
1.Osmanoğlu Ş. Investigation of radiosensitivity of gamma irradiated procaine hydrochloride in the solid state. ECJSE. 2017;4:314–318.
MLA
Osmanoğlu, Şemsettin. “Investigation of radiosensitivity of gamma irradiated procaine hydrochloride in the solid state”. El-Cezeri, c. 4, sy 3, Eylül 2017, ss. 314-8, doi:10.31202/ecjse.310494.
Vancouver
1.Şemsettin Osmanoğlu. Investigation of radiosensitivity of gamma irradiated procaine hydrochloride in the solid state. ECJSE. 01 Eylül 2017;4(3):314-8. doi:10.31202/ecjse.310494

Cited By