BACKGROUND: Mechanical ventilation is a useful supportive treatment for patients with respiratory failure who are not able to maintain the level of ventilation required to maintain the oxygenation and carbon dioxide elimination. Mechanical ventilation is often life-saving but it also has risks. Thermodynamic analyses are used to test the feasibility of processes leading to a better understanding of the systems overall performance. Energy losses (entropy) and the destruction of maximum useful work (exergy) leading to reduced respiratory work of breathing efficiency, can be calculated by thermodynamic analysis of the respiratory muscles. OBJECTIVE: To determine the entropy generation, exergy destruction and glucose consumption during and after weaning from mechanical ventilation in patients with respiratory failure by thermodynamic analysis. METHODS: In this study, a human respiratory system during and after weaning from mechanical ventilation was modelled thermodynamically using the first and second laws of thermodynamics. Work of breathing data is adapted from the literature. Mass and energy analyzes are carried out according to the 1st law of thermodynamics while entropy generation is calculated according to the 2nd law of thermodynamics which enables us to measure energy losses. In this thermodynamic model, the body temperature was considered at 37 °C, and surrounding air condition was taken at 25 °C. RESULTS: Exergy destructions during and after weaning from mechanical ventilation were calculated as 2.23x10-2 and 1.75x10-2 kJ/min, respectively. Entropy generation by the patients through the breathing cycle was 7.48x10-5 (kJ/K)/min during mechanical ventilation while 5.89x10-5 (kJ/K)/min after weaning from mechanical ventilation, respectively. The glucose consumed for work of breathing in patients during and after weaning from mechanical ventilation was calculated as 0.58-0.45 mmol/min, respectively. CONCLUSION: After weaning from mechanical ventilation, the patients have significantly decreased entropy generation, exergy destruction and glucose consumption indicating to the improvements in structure of respiratory mechanics and diaphragm perfusion. The reductions in entropy generation and exergy destruction after weaning from mechanical ventilation indicates also an increase in the mechanical efficiency of the respiratory muscles. According to the results of the energy balance analysis, the decrease in muscle energy requirement was determined and it was found by the calculations that the patient used 1.3 times more glucose during mechanical ventilation than after weaning from mechanical ventilation for work of breathing. In this study, thermodynamic approach was used to determine the benefit of mechanical ventilation. More powerful work and multidisciplinary data are needed to progress reliable procedures.

Keywords

Kaynakça

  1. Chang, D.W. (2013). Clinical Application of Mechanical Ventilation. 4th ed. Cengage Learning.
  2. Takeda, S. I., Miyoshi, S., Maeda, H., Minami, M., Yoon, H. E., Tanaka, H., ... & Matsuda, H. (1999). Ventilatory muscle recruitment and work of breathing in patients with respiratory failure after thoracic surgery. European Journal of Cardio-Thoracic Surgery, 15(4), 449-455.
  3. Mancebo, J., Isabey, D., Lorino, H., Lofaso, F., Lemaire, F., & Brochard, L. (1995). Comparative effects of pressure support ventilation and intermittent positive pressure breathing (IPPB) in non-intubated healthy subjects. European Respiratory Journal, 8(11), 1901-1909.
  4. Henning, R. J., Shubin, H., & Weil, M. H. (1977). The measurement of the work of breathing for the clinical assessment of ventilator dependence. Critical Care Medicine, 5(6), 264-268.5. Shikora, S. A., Bistrian, B. R., Borlase, B. C., Blackburn, G. L., Stone, M. D., & Benotti, P. N. (1990). Work of breathing: reliable predictor of weaning and extubation. Critical Care Medicine, 18(2), 157-162.
  5. Guyton, A., & Hall, J. (2011). In: Textbook of Medical Physiology, 12th edition, Elsevier Saunders, Philadelphia.
  6. Dincer, I., & Cengel, Y. A. (2001). Energy, entropy and exergy concepts and their roles in thermal engineering. Entropy, 3(3), 116-149.
  7. Neto, C. A., Pellegrini, L. F., Ferreira, M., de Oliveira Jr, S., & Yanagihara, J. (2010). Exergy analysis of human respiration under physical activity. International Journal of Thermodynamics, 13(3), 105-109.
  8. Mady, C. E. K., Ferreira, M. S., Yanagihara, J. I., Saldiva, P. H. N., & de Oliveira Junior, S. (2012). Modeling the exergy behavior of human body. Energy, 45(1), 546-553.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Mühendislik

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

15 Nisan 2020

Gönderilme Tarihi

18 Ocak 2020

Kabul Tarihi

23 Şubat 2020

Yayımlandığı Sayı

Yıl 2020 Sayı: 18

Kaynak Göster

APA
Çatak, J., Develi, E., & Bayram, S. (2020). Entropy Generation and Exergy Destruction During and After Weaning from Mechanical Ventilation in Patients with Respiratory Failure. Avrupa Bilim ve Teknoloji Dergisi, 18, 283-289. https://doi.org/10.31590/ejosat.690568

Cited By