Araştırma Makalesi

EEG Channel Selection using Differential Evolution Algorithm and Particle Swarm Optimization for Classification of Odorant-Stimulated Records

Cilt: 11 Sayı: 2 30 Aralık 2021
PDF İndir
EN

EEG Channel Selection using Differential Evolution Algorithm and Particle Swarm Optimization for Classification of Odorant-Stimulated Records

Öz

A significant advancement has been made in the evolutionary computing and swarm intelligence methods in past decades. These methods have been commonly used to calculate well optimized solutions. Methods select the best elements or cases among set of alternatives. In EEG signal processing applications, efficient channel selection algorithms are required to reduce high dimensionality and remove redundant features. To do this, we examined optimal 5 electrodes out of 14 using Particle Swarm Optimization (PSO) and Differential Evolution Algorithm (DEA). The proposed work is related with pleasant-unpleasant EEG odors classification problem. Classification error rates were calculated by Linear Discriminant Analysis (LDA), k-NN (k Nearest Neighbor), Naive Bayes (NB), Regression Tree (RegTree) classifiers and used as fitness function for optimization algorithms. The results showed that PSO with selected 5 channels gave lowest error rates compared with DEA for all runs. RegTree classifier generated optimal fitness function value among other classifiers. PSO algorithm can effectively support channel selection problem to identify the best channels to maximize classification performance.

Anahtar Kelimeler

Kaynakça

  1. Park, S.M., Kim, J.Y., Sim, K.B. (2018). EEG electrode selection method based on BPSO with channel impact factor for acquisition of significant brain signal. Optik (Stuttg), 155, 89–96. https://doi.org/10.1016/j.ijleo.2017.10.085.
  2. Alotaiby, T., El-Samie, F.E.A., Alshebeili, S.A., and Ahmad, I. (2015). A review of channel selection algorithms for EEG signal processing. EURASIP J. Adv. Signal Process, 66. https://doi.org/10.1186/s13634-015-0251-9.
  3. Das, S., Abraham, A., and Konar, A. (2008). Particle swarm optimization and differential evolution algorithms: Technical analysis, applications and hybridization perspectives. Stud. Comput. Intell, 116, 1–38. https://doi.org/10.1007/978-3-540-78297-1_1.
  4. Bozorg-Haddad, O., Solgi, M., Loaiciga, H. A., Meta‐Heuristic and Evolutionary Algorithms for Engineering Optimization, First, John Wiley & Sons, Inc., New JErsey, USA, 2017. www.wiley.com.
  5. Satapathy, S.K., Dehuri, S., Jagadev, A.K. (2017). EEG signal classification using PSO trained RBF neural network for epilepsy identification. Informatics Med. Unlocked, 6, 1–11. https://doi.org/10.1016/j.imu.2016.12.001.
  6. Khushaba, R.N., Al-Ani, A., Al-Jumaily, A. (2011). Feature subset selection using differential evolution and a statistical repair mechanism. Expert Syst. Appl., 38, 11515–11526. https://doi.org/10.1016/j.eswa.2011.03.028.
  7. Kroupi, E., Yazdani, A., Vesin, J.-M., and Ebrahimi, T. (2014). EEG Correlates of Pleasant and Unpleasant Odor Perception, ACM Trans. Multimed. Comput. Commun. Appl., 11, 1–17. https://doi.org/10.1145/2637287.
  8. Acharya, U. R., Fujita, H., Sudarshan, V. K., Bhat, S., and Koh, J. E. W. (2015). Application of entropies for automated diagnosis of epilepsy using EEG signals: A review. Knowledge-Based Syst., 88, 85–96.

Ayrıntılar

Birincil Dil

İngilizce

Konular

Elektrik Mühendisliği

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

30 Aralık 2021

Gönderilme Tarihi

2 Şubat 2021

Kabul Tarihi

21 Aralık 2021

Yayımlandığı Sayı

Yıl 2021 Cilt: 11 Sayı: 2

Kaynak Göster

APA
Şeker, M., & Özerdem, M. S. (2021). EEG Channel Selection using Differential Evolution Algorithm and Particle Swarm Optimization for Classification of Odorant-Stimulated Records. European Journal of Technique (EJT), 11(2), 120-125. https://doi.org/10.36222/ejt.873351
AMA
1.Şeker M, Özerdem MS. EEG Channel Selection using Differential Evolution Algorithm and Particle Swarm Optimization for Classification of Odorant-Stimulated Records. EJT. 2021;11(2):120-125. doi:10.36222/ejt.873351
Chicago
Şeker, Mesut, ve Mehmet Siraç Özerdem. 2021. “EEG Channel Selection using Differential Evolution Algorithm and Particle Swarm Optimization for Classification of Odorant-Stimulated Records”. European Journal of Technique (EJT) 11 (2): 120-25. https://doi.org/10.36222/ejt.873351.
EndNote
Şeker M, Özerdem MS (01 Aralık 2021) EEG Channel Selection using Differential Evolution Algorithm and Particle Swarm Optimization for Classification of Odorant-Stimulated Records. European Journal of Technique (EJT) 11 2 120–125.
IEEE
[1]M. Şeker ve M. S. Özerdem, “EEG Channel Selection using Differential Evolution Algorithm and Particle Swarm Optimization for Classification of Odorant-Stimulated Records”, EJT, c. 11, sy 2, ss. 120–125, Ara. 2021, doi: 10.36222/ejt.873351.
ISNAD
Şeker, Mesut - Özerdem, Mehmet Siraç. “EEG Channel Selection using Differential Evolution Algorithm and Particle Swarm Optimization for Classification of Odorant-Stimulated Records”. European Journal of Technique (EJT) 11/2 (01 Aralık 2021): 120-125. https://doi.org/10.36222/ejt.873351.
JAMA
1.Şeker M, Özerdem MS. EEG Channel Selection using Differential Evolution Algorithm and Particle Swarm Optimization for Classification of Odorant-Stimulated Records. EJT. 2021;11:120–125.
MLA
Şeker, Mesut, ve Mehmet Siraç Özerdem. “EEG Channel Selection using Differential Evolution Algorithm and Particle Swarm Optimization for Classification of Odorant-Stimulated Records”. European Journal of Technique (EJT), c. 11, sy 2, Aralık 2021, ss. 120-5, doi:10.36222/ejt.873351.
Vancouver
1.Mesut Şeker, Mehmet Siraç Özerdem. EEG Channel Selection using Differential Evolution Algorithm and Particle Swarm Optimization for Classification of Odorant-Stimulated Records. EJT. 01 Aralık 2021;11(2):120-5. doi:10.36222/ejt.873351