BibTex RIS Kaynak Göster

Aplication of two different catheters in embryo transfer

Yıl 2007, Cilt: 38 Sayı: 1, 17 - 19, 01.02.2007

Öz

Objectives: In this study our aim is to compare effects of two different catheters used in our clinic on pregnancy results Material-method: Eighty - six patients, ICSI applied and swemed or wallece catheters used during embryo transfer, were admitted to our hospital IVF center from february 2004 through 2006.SPSS was used for statistical analysis. Results: This research was conducted on 86 cases whose ages were between 21 and 37old. Wallace catheter applied 45 patients described as group 1, the other 41 patients were described as group 2. There was no statistical significance according to etiologies. From the view of clinical pregnacy outcomes and implantations there were no statistical significance between groups. Conclusion: Modern soft catheters have good effects on pregnancy outcomes in reproductive asisted teqniques. That's why selecting catheter during embryo transfer based on mostly operator choises and economic causes.

Kaynakça

  • 1-Ghazzawi IM ve ark. Transfer technique and cathater choice influence the incidence of transcervical embryo expulsion and the outcome of lVF. Hum Reprod.l999;14:677-8 2-Papageorgiou TC ve ark. Training of providers in embryo transfer:what is the minimum number of transfers required for proficency? Hum Reprod.2001 ;16:1415-9 3-Thomas C. ve ark. The degree of difficulty of embryo transfer is an independent factor for prediciting pregnancy. Hum Reprod. 2002; 17: 2632-5 4-Boone WR. ve ark. A randomize controlled trial of a soft double luman embryo transfer cathater versus a firm single luman cathater:significent improvements in pregnancy rates. Hum Reprod. 2002; 17-1502-6 5-Karenda V ve ark. A prospective randomized comparsion of the Wallace and cook, Echo-tip cathater for ultrasound guided embryo transfer
  • Fertilsteril 2002 ;77:826~30 6-Gaudas ve ark. Blood on the ET catheter is associated with decreased rates of embryo implantasyon and clinical pregnancy with the use of in vitro fertilization. Fertil Steril 1998,70:878-882

Embriyo transferinde farklı iki kateter uygulaması

Yıl 2007, Cilt: 38 Sayı: 1, 17 - 19, 01.02.2007

Öz

Amaç: Kliniğimizde kullanılan farklı tipteki 2 kateterin gebelik sonuçları üzerine etkisini değerlendirmeyi amaçladık. Materyal Metod: Şubat 2005 ve Şubat 2006 tarihleri arasında hastanesi tüp bebek Merkezinde ICSI uygulanan ve ET sırasında ya wallece ya da swemed kateter kullanılan 86 hasta çalışmaya dahil edildi. İstatistiksel analizler için SPSS (Statistical Package for Social Sciences) for Windows 10.0 programı kullanıldı. Bulgular: Çalışma, yaşları 21 ile 37 arasında değişmekte olan, toplam 86 olgu üzerinde yapılmaktadır. "Wallace" kateteri uygulanan 45 olgu "Grup I", ve "Swemed" kateteri uygulanan 41 olgu "Grup II" olarak tanımlanmıştır. Etyolojiye göre gruplar arasında istatistiksel olarak anlamlı bir farklılık bulunmamaktadır (p>0.05). Gruplar arasında implantasyon ve klinik gebelik oranları açısından istatiksel anlamlı fark saptanmamıştır. Sonuç: Yumuşak modern embryo kateterleri yardımla üreme tekniklerinde gebelik sonuçları üzerinde olumlu etkiye sahiptirler bu yüzden embriyo transfer kateterinin seçimi, çoğu kez operatörlerin tercihi ve ekonomik nedenlere dayanmaktadır.

Kaynakça

  • 1-Ghazzawi IM ve ark. Transfer technique and cathater choice influence the incidence of transcervical embryo expulsion and the outcome of lVF. Hum Reprod.l999;14:677-8 2-Papageorgiou TC ve ark. Training of providers in embryo transfer:what is the minimum number of transfers required for proficency? Hum Reprod.2001 ;16:1415-9 3-Thomas C. ve ark. The degree of difficulty of embryo transfer is an independent factor for prediciting pregnancy. Hum Reprod. 2002; 17: 2632-5 4-Boone WR. ve ark. A randomize controlled trial of a soft double luman embryo transfer cathater versus a firm single luman cathater:significent improvements in pregnancy rates. Hum Reprod. 2002; 17-1502-6 5-Karenda V ve ark. A prospective randomized comparsion of the Wallace and cook, Echo-tip cathater for ultrasound guided embryo transfer
  • Fertilsteril 2002 ;77:826~30 6-Gaudas ve ark. Blood on the ET catheter is associated with decreased rates of embryo implantasyon and clinical pregnancy with the use of in vitro fertilization. Fertil Steril 1998,70:878-882
Toplam 2 adet kaynakça vardır.

Ayrıntılar

Birincil Dil Türkçe
Bölüm Makaleler
Yazarlar

Cem Çelik Bu kişi benim

Kenan Sofuoğlu Bu kişi benim

Tansel Çetinkaya Bu kişi benim

Banu Ergül Bu kişi benim

Yayımlanma Tarihi 1 Şubat 2007
Yayımlandığı Sayı Yıl 2007 Cilt: 38 Sayı: 1

Kaynak Göster

APA Çelik, C., Sofuoğlu, K., Çetinkaya, T., Ergül, B. (2007). Embriyo transferinde farklı iki kateter uygulaması. Zeynep Kamil Tıp Bülteni, 38(1), 17-19. https://doi.org/10.16948/zktb.18460
AMA Çelik C, Sofuoğlu K, Çetinkaya T, Ergül B. Embriyo transferinde farklı iki kateter uygulaması. Zeynep Kamil Tıp Bülteni. Şubat 2007;38(1):17-19. doi:10.16948/zktb.18460
Chicago Çelik, Cem, Kenan Sofuoğlu, Tansel Çetinkaya, ve Banu Ergül. “Embriyo Transferinde Farklı Iki Kateter Uygulaması”. Zeynep Kamil Tıp Bülteni 38, sy. 1 (Şubat 2007): 17-19. https://doi.org/10.16948/zktb.18460.
EndNote Çelik C, Sofuoğlu K, Çetinkaya T, Ergül B (01 Şubat 2007) Embriyo transferinde farklı iki kateter uygulaması. Zeynep Kamil Tıp Bülteni 38 1 17–19.
IEEE C. Çelik, K. Sofuoğlu, T. Çetinkaya, ve B. Ergül, “Embriyo transferinde farklı iki kateter uygulaması”, Zeynep Kamil Tıp Bülteni, c. 38, sy. 1, ss. 17–19, 2007, doi: 10.16948/zktb.18460.
ISNAD Çelik, Cem vd. “Embriyo Transferinde Farklı Iki Kateter Uygulaması”. Zeynep Kamil Tıp Bülteni 38/1 (Şubat 2007), 17-19. https://doi.org/10.16948/zktb.18460.
JAMA Çelik C, Sofuoğlu K, Çetinkaya T, Ergül B. Embriyo transferinde farklı iki kateter uygulaması. Zeynep Kamil Tıp Bülteni. 2007;38:17–19.
MLA Çelik, Cem vd. “Embriyo Transferinde Farklı Iki Kateter Uygulaması”. Zeynep Kamil Tıp Bülteni, c. 38, sy. 1, 2007, ss. 17-19, doi:10.16948/zktb.18460.
Vancouver Çelik C, Sofuoğlu K, Çetinkaya T, Ergül B. Embriyo transferinde farklı iki kateter uygulaması. Zeynep Kamil Tıp Bülteni. 2007;38(1):17-9.